background image

 

 

 

 

 

 

 

 

 

 

USER’S MANUAL 

 

 

 

 
 

 

 

 

PSE-308R/316R/324R 

Power Source Equipment 

(AC+DC Input, Gigabit PoE Midspan)

 

 

Summary of Contents for PSE-308R

Page 1: ...USER S MANUAL PSE 308R 316R 324R Power Source Equipment AC DC Input Gigabit PoE Midspan ...

Page 2: ...lity Installation 4 GUI Management Display and Illustration System Login Modify Password Edit Station TCP IP Edit Remote PoE IP GUI Connect All Single Station Connect Disconnect Station and Status Window Select Edit Port Name Configuration Factory Setting Board Status Port Status GUI Version GUI Disconnect All File Open and Save 5 Technical Specification 3 3 4 4 4 4 5 5 6 6 7 14 15 15 16 17 18 20 ...

Page 3: ... networked device is PoE capable and power is never transmitted unless a Powered Device is at other end of the cable It also continues to monitor the channel If the Powered Device does not draw a minimum current because it has been unplugged or physically turned off the PSE shuts down the power to that port Devices which are not equipped to receive power over Ethernet may require an external split...

Page 4: ...tents of your PSE 308R 316R 324R package with the standard checklist above IF any item is missing or damaged please contact your local dealer for service 2 Hardware Description This Section mainly describes the hardware of the PSE 308R 316R 324R and gives a physical and functional overview Physical Dimension PSE 308R 316R 324R physical dimension is 430mm x 290mm x 44mm Lx W x H 1U 19 or 23 Rack mo...

Page 5: ...iptions of LED status and their meaning LED Status Color Description RJ45 On Green A network device is detected 10 100 1000 Mbps but no communication activity is detected Blinking Green The Ethernet port is transmitting to or receiving package from another device Off No device is detected Power On Green Power feeding normally On Red Power or fan alarm Off Power off Ports On Green Power feeding Bli...

Page 6: ...ide of power cord connects to the power outlet The internal power supply of the PSE works with the voltage range of 100V 240VAC frequency 50 60Hz or with voltage range of DC 42V 57V Check the port the power indicator will self test on the front panel to see if power is properly supplied Network Application The PSE can provide power to the PD which follow the IEEE 802 3af standard in the network It...

Page 7: ...y that PSE 308R 316R 324R is properly installed on your network and PC on the network can access PoE via the web browser 1 Verify that PC network interface card NIC is operational on the TCP IP protocol 2 Supply power to PSE 308R 316R 324R 3 Use RJ45 cable connect PSE308R 316R 324R direct to your PC 4 Make sure the PSE 308R 316R 324R default IP is 192 168 1 10 5 Set your PC IP to 192 168 1 2 or ot...

Page 8: ...r next 9 Key in ID user name and password to enter PoE TCP IP parameter setting Default ID and password is admin and system 10 PSE 308R 316R 324R TCP IP parameter has 4 pages interface administrator setting TCP Mode UDP Mode and UART You must change the administrator TCP mode to fit your network ...

Page 9: ...t Mask You can assign the subnet mask for the IP address The default subnet mask is 255 255 255 0 Gateway You can assign the gateway here The default gateway is 192 168 1 1 IP Configure You must assign to Static for PoE serve operation The default IP configure is Static Username You can assign new user name The default setting is admin Password Confirm You can type in new password here The default...

Page 10: ...er for PoE management operation Port Number You can assign port number for TCP IP operation The default Port Number is 23 Remote Server IP Address Unused Clint mode inactive timeout Unused Server mode protect timeout Set to 0 Disable for normal operation When you have finished the set up click on Update to update your setting ...

Page 11: ...User s Manual PSE 308R 316R 324R 11 13 UDP Mode This mode is not used in the PoE application ...

Page 12: ...600 bps for PoE operation Character Bits Set to 8 bits for PoE operation Parity Type Set to none parity for PoE operation Stop Bit Set to 1 stop bit for PoE operation Hardware Flow Control Set to none flow control for PoE operation When you have finished the set up click on Update to update your setting PS The PSE 308R 316R 324R don t used in the Telnet terminal ...

Page 13: ...User s Manual PSE 308R 316R 324R 13 15 When you have configured your set up you must reset the device to take effect ...

Page 14: ...PoE and view the PD parameter information The software utility provides GUI interface and it is easy to install The software utility supports Windows environment Window 98 2000 XP Vista and Window 7 Please follow the below steps to install the software utility 1 Insert the software utility CD ROM into your CD ROM drive 2 Run the setup exe 3 You will see the installation screen display 4 Then click...

Page 15: ... software utility Netclient You will see the main utility interface below Tools bar PSE station selection alarm indicator Display PSE station PSE station name IP setting Display page select PSE port name setting legend tool PSE power fan alarm indicator message window PSE port 9 16 status PSE alarm summary PSE port 1 8 status PSE port 17 24 status ...

Page 16: ...User s Manual PSE 308R 316R 324R 16 System Login Run the management software the system will show the diagram below Now enter the password first enter the default setting which is 0000 ...

Page 17: ...User s Manual PSE 308R 316R 324R 17 Modify Password Click File and select Modify PSW you can modify the password the system permits 3 sets of password ...

Page 18: ...User s Manual PSE 308R 316R 324R 18 Edit Station TCP IP Click Setting and select LAN Setting or click LAN Setting icon the screen will enter IP Setting window ...

Page 19: ...P address and port number Click the Edit icon to modify this parameter In the Edit window click the View icon to display TCP IP parameter Station Name You can assign a name to the PSE device Address You can assign the IP address for this PSE station Port You can assign the port number for this PSE station ...

Page 20: ...rowser To modify the remote PoE TCP IP parameter please reference RJ 45 Remote Control Port of section 2 Hardware Description page 7 Change Browse icon You can use this icon to change the web browser for remote PoE IP edit The default web browser is Microsoft Internet Explorer CLOSE icon close IP Setting window return to main page window ...

Page 21: ...age window click GUI and select Connect All command or click connect all icon if the Station Selection window shows the name icon and displays power status green or red light it means that the PSE connection is correct You can then select station to configure you PSE ...

Page 22: ...ple In the Station Selection window the LED indicates real time connection of PSE Green this connection and PSE power are normal Red this connection is OK but PSE power is not correct Orange this connection is not working Gray this station is not setting ...

Page 23: ...connect In the IP Setting window you can click Connect Disconnect icon to enable disable single station connection the LED indicates real time status of TCP IP Green TCP IP connection is OK Red TCP IP connection is not working Gray TCP IP parameter is not setting ...

Page 24: ...TCP IP parameter In the GUI Connector mode there two display windows can choose Port Status Board Setting Port status and Board Setting show relative PSE Station status If you want to change the status display window only use the mouse to choose the relative word icon If you want to change the station also use the mouse to choose the station name icon Station Select display icon Status display ico...

Page 25: ... Edit Port Name Click Setting and select PoE Name or click the PoE Name icon The screen will enter IP Setting window You can assign a name to the PSE port individually In the Module Select window select the suitable port that you require ...

Page 26: ...etting to PSE system You can setup Operation Mode AC Disconnect DC Disconnect of each port individually then click Set PSE port operates in one of three modes auto mode force mode and shutdown mode In auto mode the port will detect and classify a PD to connect to then immediately turn on the power if the detection was successful In force mode the port will not detect and classify a PD to connect t...

Page 27: ... s Manual PSE 308R 316R 324R 27 Factory Setting Click Config and select Factory or click the Factory icon The screen will show the factory setting control panel as below then click Y for the Factory Setting ...

Page 28: ...User s Manual PSE 308R 316R 324R 28 Factory setting as below Operation Mode Auto Auto Force Shutdown AC Disconnect On On Off DC Disconnect Off On Off ...

Page 29: ...User s Manual PSE 308R 316R 324R 29 Board Status Click Config and select GetBoardStatus or click Board STATUS icon the screen will show current status of each port ...

Page 30: ...sDisp and select PortStatus or click the PORT STATUS icon the screen will show current status of each port and current power supply status of each module If all power modules are working normally the Sys Power will show a green light if any module has failed the light will turn to red ...

Page 31: ...User s Manual PSE 308R 316R 324R 31 GUI Version Click StatusDisp and select GUI Version the screen will show the version of the EMS utility ...

Page 32: ...User s Manual PSE 308R 316R 324R 32 GUI Disconnect All Click the GUI and select Disconnect All or click the GUI disconnect all icon to disconnect the communication between GUI and PSE ...

Page 33: ...r s Manual PSE 308R 316R 324R 33 File Open and Save You may click File and select Open or click the Open file icon to open the previous setting file Click Save or Save file icon to save the current setting ...

Page 34: ...ole Port 1 RJ45 console interface for management Output power Per port DC 48V 350mA 16 8W Maximum Pair4 5 Pair7 8 Power consumption maximum 134W 268W 403W AC Input 100 240VAC 50 60Hz DC Input DC 56V 42V 57V Environment Operating Temperature 0 40 Storage Temperature 20 80 Humidity 10 95 RH non condense Dimensions 430mm L x 290mm W x 44mm H 19 Rack Mount 1U Weight 3 2kg 3 9kg 4 6kg ...

Reviews: