6.4
V-SHOCK EDGE Tieback Fall Clearance Charts
6 ft V-SHOCK EGDE Tieback PFL:
6 ft / 1.8 m Li 2 ft / 0.6 m Tieback (Total Length: 8 ft / 2.4 m)
10 ft V-SHOCK EGDE Tieback PFL:
10 ft / 3 m Li 2 ft / 0.6 m Tieback (Total Length: 12 ft / 3.6 m)
V-SHOCK EDGE Tieback Single PFL
V-SHOCK EDGE Tieback Twin PFL
Product: V-SHOCK EDGE Tieback PFL
Use:
Leading edge applications
Capacity:
≤ 310 lbs (141 kg)
(A)
Clearance values shown are based on 2 ft (0.6 m)
anchorage setback from the leading edge. Anchorage
connector may be used at setback distance of 2 ft (0.6
m) from the leading edge or as far back as required.
For every 1 ft (0.3 m) the anchorage location is set
back from the initial 2 ft (0.6 m) setback, the user can
subtract 0.5 ft (0.15 m) from the clearance provided in
the chart based on the user's offset distance.
If the V-SHOCK EDGE Tieback PFL is anchored
around a structural member that has been suitably
identified by a qualified person, the initial setback of 2
ft (0.6 m) may be reduced by an amount equal to the
circumference of the object, up to 2 ft (0.6 m).
NOTE:
Clearance chart anchorage location for
illustrative purposes only.
ILLUSTRATION NOT TO SCALE
WARNING!
* In leading edge applications with 0 ft (0 m) setback, ensure that setup does not allow snaphook to contact leading edge in
the event of a fall.
Failure to follow this warning can result in serious personal injury or death.
US
V-SHOCK® & V-SHOCK® EDGE
Personal Fall Limiter (PFL)
20
6 Fall Clearances
US