USING THE COMPRESSED AIR BREATHING APPARATUS
MSA
20
AirMaXX classic
3.3. Connecting Two Compressed Air Cylinders
3.3.1. Pressure Reducer with Thread Connection
Fig. 14
SCBA apparatus with two compressed air cylinders
3.3.1.1. Preparing the Apparatus for Use with Two Compressed Air Cylinders
(1) Hinge up the cylinder separator to a vertical position in the middle of the
cylinder support until it catches.
(2) Connect T-piece to high pressure socket of pressure reducer.
3.3.1.2. Connecting Two Compressed Air Cylinders
(1) Place compressed air breathing apparatus horizontally so that the back face
is uppermost (
(2) Hinge cylinder separator (1) into a vertical position until it catches.
(3) If there is no T-piece connected to the pressure reducer, check gaskets on
the pressure reducer and T-piece and thread in T-piece loosely.
(4) Open tension clamp on cylinder strap eliminating any tension by extending the
strap to full length pulling the small bar at the tension clamp (
(5) Push one compressed air cylinder through the cylinder retaining strap so that
the cylinder valve points to the T-piece, and lies on one of the outer supports.
(6) Loosely screw the cylinder valve onto the T-piece.
(7) Push a second compressed air cylinder through the cylinder retaining strap
so that the cylinder valve points to the T-piece, and lies on the other outer
support.
(8) Loosely thread the second cylinder valve onto the T-piece.
With right-angled T-piece, align the compressed air cylinders by hinging
the pressure reducer and pulling the cylinders together (see Operating
Manual for T-pieces).
(9) Tighten all three high pressure connection handwheels.