d. Use the instructions on the label to prepare a solution of Confidence Plus Germicidal Cleaner (P/N 10009971) in a
bucket or sink.
e. Submerge the facepiece, hood, and support belt in the solution. Scrub gently until clean.
f. Rinse facepiece and components in clean, warm (110°F), preferably drain to remove the solution, then air-dry.
g. Use a damp cloth or sponge saturated with the solution to wipe the breathing tube.
NOTICE
The primary facepiece lens may be polycarbonate and may be scratched if rubbed with coarse dry cloth or paper towels.
h. Reassemble the respirator and store in a cool, dry place out of direct sunlight. Do not store the respirator or
components within or near an area where respirator or components could be exposed to substances that could
attack any part, causing the parts NOT to perform as designed and approved.
8
Maintaining the Respirator
WARNING!
Only trained personnel are to maintain the respirator. Use only genuine MSA parts. Do not make repairs or design
modifications other than as recommended by MSA or the NIOSH approval will be voided.
Failure to follow this warning can result in serious personal injury or death.
Regular maintenance and inspection of components of the respirator are necessary to assure proper protection. In addition, the
NIOSH approvals require that you regularly inspect this unit. Parts found to be worn or damaged must be replaced. See the
parts list for correct replacement part numbers.
WARNING!
Inspect the respirator after it has been cleaned and sanitized. The respirator must be inspected before it is used again.
Failure to follow this warning can result in serious personal injury or death.
8.1
Inspection
1. Check the hood for tears or holes.
US
Abrasi-Blast Respirator
24
8 Maintaining the Respirator