MS Sedco ID20 Installation Instructions Download Page 1

ID20 

Industrial Door Microwave Motion Sensor 

INSTALLATION INSTRUCTIONS 

Page 1

(/MANU) ID20v0913

Section 1

General Description

The  ID20  is  a  long  range  microwave  motion  sensor  for 

activating automatic industrial doors.  Features include a 

speed  selectable  switch  that  makes  the  unit  capable  of 

detecting  pedestrians  and/or  vehicles.    Detection  mode 

is  selectable  between  approach-only  or  depart-only 

motion and the weatherproof housing makes it ideal for 

installation in exterior applications.

Microwave  technology  allows  the  ID20  to  detect  larger 

objects,  such  as  forklift  trucks,  up  to  60  feet  away.  

Maximum pattern size is approximately 18 ft. wide at 60 

ft.  from  the  unit  and  is  adjustable  via  a  range 

potentiometer  on  the  printed  circuit  board.    The  ID20  is 

not  affected  by  air  motion,  change  in  temperature, 

humidity, color or background variations.

Section 2

Installation

Mounting (Fig. 1)

1.  Remove 1/4-20 hinge bolt holding the mounting 

 

bracket to the sensor housing and detach the 

 

mounting bracket.

2.  Using the mounting bracket as a template, mark and 

 

drill mounting holes in the desired location.

3.  After attaching the mounting bracket in the desired 

 

location, re-attach the sensor housing to the 

 

mounting bracket with the 1/4-20 hinge bolt 

 

removed in step 1.

Wiring (Fig. 2)

Wiring the sensor must be done with the sensor cover off.  

Remove  the  four 

hex  head

  screws.    Two  are  located  on 

the  front  plate  and  two  are  located  on  the  back  plate.  

The cover is then removed by lifting up slightly and sliding 

forward (Fig. 1).  

1.  With Power off, pull 4 conductor cable through the 

 

wire fitting and make all wiring connections to the 

 

terminal block located on the printed circuit board 

 

(Fig. 2).

 

NOTICE: 

 Operating voltage is 12V to 24V AC or 

 

DC and should be applied through the 

 

transformer supplied with the unit.  Allow the 

 

device 10 seconds to warm up once power is 

 

applied.

 

WARNING: 

 Do Not ground one side of the 

 

secondary of the supply transformer.  Circuit 

 

ground of the unit is electrically connected to 

 

the housing.  Grounding one side of the 

 

transformer may create a direct short that will 

 

permanently damage the unit.

 

NOTICE: 

 4 conductor cable, 18 to 22 gauge 

 

conductor size, 3/16” to 5/16” cable O.D. is 

 

recommended. 

For more information, call us toll-free at (317) 842-2545.

Set Up & Alignment (Fig. 2)

1.  Set up the sensor parameters via the 4 dip switches 

 

and 2 position slide switch located on the printed 

 

circuit board (Fig. 2).

 

NOTICE: 

 Dip switch #2 provides speed 

 

detection adjustment.  ON = detection of 

 

vehicles & pedestrians traveling 3 mph+.  OFF = 

 

detection of objects & pedestrians traveling 1 

 

mph+.  For installations where pedestrian 

 

detection is not desired, set dip switch #2 to 

 

ON. 

 

NOTICE: 

 Dip switches 3 & 4 are not used. 

2.  Align the ID20 by adjusting the range potentiometer 

 

and aiming angle to achieve the desired pattern 

 

placement and size.  To adjust the sensor’s aiming 

 

angle, loosen the 1/4-20 hinge bolt, adjust and 

 

retighten.

 

NOTICE: 

 A time delay adjustment potentiometer 

 

is available to adjust the amount of time the 

 

relay stays energized after detection is lost. 

3.  An LED located on the main printed circuit board will 

 

illuminate when the relay has changed state in 

 

response to motion providing a visual indication that 

 

the unit is working.

4.  Once set up and alignment is completed, replace the 

 

cover and ensure that all bolts and screws are 

 

tightened. 

 

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Summary of Contents for ID20

Page 1: ...terminal block located on the printed circuit board Fig 2 NOTICE Operating voltage is 12V to 24V AC or DC and should be applied through the transformer supplied with the unit Allow the device 10 seconds to warm up once power is applied WARNING Do Not ground one side of the secondary of the supply transformer Circuit ground of the unit is electrically connected to the housing Grounding one side of ...

Page 2: ...cket predrilled slotted Temperature 35 F to 165 F 35 C to 74 C Weight 3 5 lbs 1 6 kg Size 7 x 4 x 4 17 8cm x 10 2cm x 10 2cm Color Enclosure Aluminum black powder coat finish Section 5 Warranty MS SEDCO guarantees this product to be free from manufacturing defects for one year from date of installation Unless MS SEDCO is notified of the date of installation the warranty will be in effect for one y...

Page 3: ...UCTIONS Page 3 MANU ID20v0913 FIGURE 1 Mounting Bracket Base Cover Wire Fitting Hex Head Cover Screw 2 Hex Head Cover Screw 2 1 4 20 Hinge Bolt ID20 Housing 8701 Castle Park Drive Indianapolis Indiana 46256 Telephone 317 842 2545 www mssedco com custsvc mssedco com ...

Page 4: ...y Connections 4 Normally Open N O 5 Common 6 Normally Closed N C NOTE Relay is with power applied and unit setup for Failsafe operation Time Delay Adjustment 0 to 5 seconds Clockwise to increase counterclockwise to decrease NOTES 1 The LED Indicator is illuminated whenever the Relay is activated 2 The Range Adjustment allows the Pattern Distance to be varied for each individual installation 3 The ...