General Description

The PTM is a timing module that allows users to control 

an automatic door operator for a room where privacy is a 

concern, such as a washroom, restroom, clean room, or 

photo development room.  From the outside of the room, 

users are able to activate the door.  Once inside, users 

are able to lock the door which prevents access from the 

outside “push to open” button.  When egress is desired, 

the user presses an inside “push to open” button which 

deactivates the lock and activates the door.  A keyswitch 

override is present on the exterior, as well as LEDs to 

indicate if the room is occupied.  Green indicates 

available while red indicates occupied.

The delay time between deactivating the lock and 

activating the door, as well as the “on time” for door 

activation are fully programmable.

 

WARNING: 

 Devices to be controlled by the PTM

 

must be low voltage (12-24V) but can be 

 

inductive loads.  Surge suppressors are standard

 

on the PTM.

OPTIONS:

PTM

 = Privacy Timing Module

PTM-HDWE

 = Prewired Harness to Terminal Block & 

Magnetic Door Position Switch

PTM-KIT 

= Turnkey Kit Includes PTM, PTM-HDWE & 

Switches (830B-59J-PTM, 59V-PTM)

WET/DRY CONTACT OPTION:

The PTM has the option to supply power to Relay Output 

1 contacts.  This is known as having a "Wet" contact 

instead of the conventional "Dry" contact closure.  To use 

output 1 as a "Wet" contact, change the jumper setting 

(see Figure 1).  The voltage supplied to Output 1 will be 

the same as the voltage supplied to the input power wires 

of the PTM.

 

WARNING: 

 Changing jumper settings to enable 

 

the “Wet” Contact option will apply a voltage to 

 

the Output 1 relay contact. Please ensure that 

 

any device connected to this output is capable of 

 

accepting voltage. Failure to do so may result in 

 

damage to the device.

 

WARNING: 

 If the “Wet” Contact Option is to be 

 

used, please ensure that no more than a 

 

maximum of 3A current is to be supplied by the 

 

PTM. Failure to do so may result in damage to 

 

the PTM.

Section 2

Basic Installation

1.  Mount the PTM in desired location.

2.  With power off, make all necessary wiring 

 

connections to the wiring harnesses (Fig. 1) or 

 

Pre-wired Terminal Block (Fig. 2).

 

Figure 1:  PTM Layout and Wiring Connections

 

NOTICE:

  These instructions are provided for your 

 

convenience.  Please verify your installation is in 

 

compliance with all applicable standards upon

 

completing installation of this device.

Section 3

Technical Data

Model.................................... PTM

Input Power........................... 12-24V AC or DC

Power Consumption............. 2W Maximum

Output Contacts................... Form C, Rated at 3 Amps

Relay Contact Rating............ 3A:120V AC; 3A:60V DC

Temperature Rating............. -22°F to 158°F 

 

(-30°C to 70°C)

Weight................................... <0.25  lbs.

Physical Size......................... 4.75"L x 2.125"W x 0.75"H

Section 4

Warranty

MS SEDCO guarantees this product to be free from manufacturing 

defects for 1 year from date of installation.  Unless MS SEDCO is 

notified of the date of installation, the warranty will be in effect for 

1 year from the date of shipment from our factory.  If, during the 

first year, this device fails to operate and has not been tampered 

with or abused, the unit can be returned prepaid to factory and it 

will be repaired free of charge.  After 1 year, the unit will be 

repaired for a nominal service charge.  

This limited warranty is in 

lieu of all other warranties expressed or implied, including any 

implied warranty of merchantability, and no representative or 

person is authorized to assume for MS SEDCO any other liability 

in connection with the sale of our products.  All warranties are 

limited to the duration of this written warranty.  In no event 

shall MS SEDCO be liable for any special, incidental, 

consequential or other damages arising from any claimed 

breach of warranty as to its products or services.

Questions?  Call us toll-free at 1-317-842-2545 or

visit us online at www.mssedco.com.

!

!

!

!

                        Privacy Timing Module 

INSTALLATION INSTRUCTIONS

The 

Commander 

Series

PTM

7898 Zionsville Road 

 Indianapolis, Indiana 46268

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Commander PTM

Page 1: ...M Failure to do so may result in damage to the PTM Section 2 Basic Installation 1 Mount the PTM in desired location 2 With power off make all necessary wiring connections to the wiring harnesses Fig 1 or Pre wired Terminal Block Fig 2 Figure 1 PTM Layout and Wiring Connections NOTICE These instructions are provided for your convenience Please verify your installation is in compliance with all appl...

Page 2: ...nnections Input Connections Wht Blue Wht Gra Input Power 12 24V AC or DC Switch Input 1 Inside Push to Open Switch Switch Input 2 Outside Key Switch and Latchbolt or Inside Lever Monitor if used Switch Input 3 Inside Push to Lock Switch Switch Input 4 Outside Push to Open Switch Output Connections Orange Brown Yellow Violet White Gray Output 1 Output 2 COM N O N C COM N O N C Input Actions Input 1...

Page 3: ...c o1 output 1 n o n c 01 dry 01 wet Output 1 Output 2 INPUT 4 INPUT 3 INPUT 2 CO M CO M PTM Wire Harness is Prewired to Terminal Block Wht Brn Wht Gray Wht Vio Wht Grn Wht Red Wht Blue Blue Green Green Auto Door Control Activation Circuit NOTE 1 All LEDs provided have built in resistors 2 Strike shown is wired fail safe Door can be opened if power fails 3 Strike and power voltages must match Green...

Page 4: ...rike Red LED Vcc 24V Door Activation O P E N O P E N L O C K U N L O C K NOTE Additional Red LED s are connected in parallel with the one shown Key Red Green Unlock Open Outside Inside Lock NC NO COM Guard Magnetic Switch on Door Bypass Switch 7898 Zionsville Road Indianapolis Indiana 46268 Telephone 317 842 2545 www mssedco com custsvc mssedco com All manuals and user guides at all guides com ...

Reviews: