LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
Right LDx00
Basic Contents: Same as for left LDx00.
Options: Same as for left LDx00.
Cabling
Inter-LDx00 Cabling
For each pair of GM2s, one in the left LDx00 and the other in the right LDx00, occupying slots of
the same number, interconnect the trunk ports (
TRUNK TX
and
TRUNK RX
) of one GM2 to the
trunk ports (
TRUNK RX
and
TRUNK TX
) of the other GM2 with a fiberoptic cable.
Intra-LDx00 Cabling
None.
LDx00 to RS-232/Ethernet Cabling
LDx00-to-RS-232: As shown in Figure 78.
LDx00-to-Ethernet: As shown in Figure 79.
Data Flow
Left LDx00
Data on Gigabit Ethernet channels to a GM2 in the left LDx00 are multiplexed and sent to the
GM2 at the other end of the link in the right LDx00 where they are demultiplexed to continue on
their respective channels.
Right LDx00
Same as for left LDx00 but in the opposite direction.
Figure 36: GM2 Outband Point-to-Point Topology
92