LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
SFP Module
1. Holding the SFP module with the right side up, slide it about half-way into the SFP
receptacle.
2. If the SFP module has a latching mechanism, while holding the SFP module with one
hand gently release the latch with the other hand. Usually, the latch handle is a wire
frame around the SFP module. To release the latch, swing down the wire frame.
3. With both thumbs pressed against the face edges of the SFP module, gently slide it as
far into the SFP receptacle as possible. Holding the SFP module in this position, swing
up the latch handle around the SFP module to latch it.
Cabling
Module to Module
General
This section shows how modules are to be cabled to each other.
Fiberoptic cables (jumpers) for module-to-module cabling within the same LDx00 are provided by
MRV
. The cables are labeled so that they can be connected to the right connectors.
Note
For convenience, connect the jumper fiberoptic cables via the LDx00 guide
(shown in Figure 2).
Fiberoptic cables for LDx00 to LDx00 (or LDx00 to access equipment) must be supplied by the
customer.
Mux to Demux External Cabling
Figure 43: Mux to Demux Cabling
between
LDx00s
115