MRU GmbH
SWG 100 BIO Ex User Manual
Page
140
of
150
64
FL
v-gas [m/s]
(unit depends on user settings)
66
FL
Flow vol. [m³/s]
(unit depends on user settings)
68
FL
Net calorific value [MJ/m³]
Status & measurement values of sample point 1
70
U32
Analyser Status
(more details read below)
72
U32
System Alarm
(more details read below)
74
72
FL
O2 [%]
76
76
FL
CO2 [%]
78
80
FL
CH4 [ppm]
(or CH4 [%], if measured in %)
80
84
FL
H2S [ppm]
82
88
FL
H2 [ppm]
(or H2 [%], if measured in %)
84
92
FL
CO [ppm]
(or CO [%], if measured in %)
86
96
FL
NO [ppm]
88
100
FL
SO2 [ppm]
90
104
FL
NO2 [ppm]
92
108
FL
T-gas [°C/°F]
(unit depends on user settings)
94
112
FL
v-gas [m/s]
(unit depends on user settings)
96
116
FL
Flow vol. [m³/s]
(unit depends on user settings)
98
FL
Net calorific value [MJ/m³]
Status & measurement values of sample point 2 (optional)
100
U32
Analyser Status
(more details read below)
102
U32
System Alarm
(more details read below)
104
120
FL
O2 [%]
106
124
FL
CO2 [%]
108
128
FL
CH4 [ppm]
(or CH4 [%], if measured in %)
110
132
FL
H2S [ppm]
112
136
FL
H2 [ppm]
(or H2 [%], if measured in %)
114
140
FL
CO [ppm]
(or CO [%], if measured in %)
116
144
FL
NO [ppm]
118
148
FL
SO2 [ppm]
120
152
FL
NO2 [ppm]
122
156
FL
T-gas [°C/°F]
(unit depends on user settings)
124
160
FL
v-gas [m/s]
(unit depends on user settings)
126
164
FL
Flow vol. [m³/s]
(unit depends on user settings)
128
FL
Net calorific value [MJ/m³]
Status & measurement values of sample point 3-4 (optional)
130-189
168...
...
add 30/48 to the addresses for each sample point
Note: Optional AUX values are not available via Profibus!
(at least not with the delivered Profibus configuration)
protoco
l
address
data
type
numb. of
registers
register content
AUX-values (read by up to 10 IO-modules)
190
FL
2
AUX-value read by IO-module 1 - Input 1
192
FL
2
AUX-value read by IO-module 1 - Input 2
194
FL
2
AUX-value read by IO-module 1 - Input 3
196
FL
2
AUX-value read by IO-module 1 - Input 4
198
FL
2
AUX-value read by IO-module 2 - Input 1
200
FL
2
AUX-value read by IO-module 2 - Input 2
202
FL
2
AUX-value read by IO-module 2 - Input 3
Summary of Contents for SWG100 BIOEX
Page 1: ...9512EN BIOEX SWG100 BIO EX USER MANUAL...
Page 2: ...MRU GmbH SWG 100 BIO Ex User Manual Page 2 of 150...
Page 30: ......
Page 47: ...MRU GmbH SWG 100 BIO Ex User Manual Page 47 of 150...
Page 48: ......
Page 98: ......
Page 106: ......
Page 122: ......
Page 147: ...MRU GmbH SWG 100 BIO Ex User Manual Page 147 of 150 20 Declaration of conformity...
Page 148: ...MRU GmbH SWG 100 BIO Ex User Manual Page 148 of 150...
Page 149: ...MRU GmbH SWG 100 BIO Ex User Manual Page 149 of 150...
Page 150: ...MRU GmbH SWG 100 BIO Ex User Manual Page 150 of 150 EN_V3 0_BIO EX...