Installation MRD TNM4000
Release 02 12/2020
Industrial Switch >TNM4000
30
2.3
Basic set-up
The basic settings of the device can be found in the “CLI Manual
”
and “GUI Manual”
on the CD/DVD.
Default settings
IP address: 192.168.2.1
Password for management:
Login: admin; password: admin
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB.
CLI data rate: 9,600 Baud or 115,200 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated
Optical ports: autonegotiation
CLI interface (external management)
The CLI interface is an RJ45 socket.
The CLI interface is a serial interface which allows you to connect the following
devices locally:
An external management station (a super Windows terminal or PC with
appropriate terminal emulation). This enables you to set up a connection to
the Command Line Interface (CLI) and to the system monitor.
Settings
Speed
9,600 Baud
Data
8 bits
Stopbit
1 bit
Handshake
off
Parity
none
Table 7: default settings of CLI interface
The socket housing is electrically connected to the front panel of the device.
The CLI interface is not electrically isolated from the supply voltage.