Power Supply
Measurement Tolerance
Supply Voltage
12-24V DC
Contact Resistance
1% +0.01
Ω
Power consumption (Typical)
<10W
Coil Resistance
1% +1
Ω
Power consumption (Peak)
<45W
Coil Voltage
1% +0.1V
Power Connector
Amphemol LTW
BD-02
Coil Current
1% +1mA
Output to Relay
Design & Test Standards
Maximum Power
35W
See CE Declaration of Conformity
Maximum Current
1A
Environmental performance
Voltage- RelayDoc
50V DC maximum
Climatic categories to IEC60721
Voltage- RelayDoc-HV
130V DC maximum
3.1 Storage
TBA
3.2 Transport
TBA
Interface
3.3 Stationary
TBA
Display
5” Backlit Colour LCD 800x600 Class- Mechanical conditions to IEC60721
Touch Screen
Capacitive
3.1 Storage
TBA
Embedded menus
Yes
3.2 Transport
TBA
Authentication
Required
3.3 Stationary use
TBA
Authentication method
PIN
EMC Performance
Standard Test
Result
Connectivity
Immunity
USB
USB Type A
ESD
IEC 61000-4-2
B 6kV/8kV
Network
Ethernet 10/100Mb
Radiated
IEC 61000-4-3
A
Calibration
DB9
Radio Frequency
Physical properties
Electromagnetic Field
IEC 61000-4-3
A
Enclosure
Aluminium
Fast Transient/Burst
IEC 61000-4-4
B
Dimensions, mm
280x180x120 typical
Surge
IEC 61000-4-5
B
Installation Clearance
50mm, all round
Conducted disturbance
IEC 61000-4-6
A
Weight (Device only)
2.7kg typical
Interference emission
Wall Mount
Recommended
HF Radiation
EN 50121-4 &
Pass
Mounting System
Using 4x fasteners
HF Conducted
EN61000-6-3
Pass
Tabletop usage
Optional
Operating position
Vertical or Horizontal
Warranty
Operating environment
0
o
C - 45
o
C
Duration
Twelve Months
IP Rating (Internal/Terminals)
IP30
Type
Parts & Labour, Return to Supplier
Flammability Rating (Enclosure)
UL94-V0
Other
Unlimited Support by Telephone & Email