background image

G ( Gauss), mT ( milli Tesla ), USB/RS232

AC/DC MAGNETIC METER

Your purchase of this
AC/DC MAGNETIC METER
marks a step forward for
you into the field of
precision measurement.
Although this METER is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operating techniques are
developed. Please read the
following instructions
carefully and always keep
this manual within easy
reach.

Model : MG-3002

       OPERATION MANUAL

3, Hagavish st. Israel 58817   Tel: 972 3 5595252, Fax: 972 3 5594529 

[email protected]

 

MRC. 

5

.1

8

Summary of Contents for MG-3002

Page 1: ...Although this METER is a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are developed Please read the following instructions carefull...

Page 2: ...RS 232 Output Terminal 4 3 13 Reset button 4 3 14 DC 9V Power Adapter Input Socket 4 3 15 Stand 4 3 16 Tripod Fix Nut 4 3 17 Battery Compartment Cover 4 3 18 Battery Cover Screw 4 4 MEASURING PROCEDU...

Page 3: ...compensation Zero button for DC magnetic function Separate probe easy operation and convenient for remote measurement Data hold function for freezing the desired value on display Records Maximum and...

Page 4: ...0 mT x 0 1 mT G Range 1 1 500 0 G x 0 1 G Range 2 15 000 G x 1 G Accuracy DC 5 rdg 10 digit AC 5 rdg 20 digit Frequency AC measurement Response 50 Hz 60 Hz Sensor Hall sensor Temp Probe head build the...

Page 5: ...Current Approx DC 20 5 mA Weight Approx 270 g 0 60 LB include battery probe Dimension Main instrument 195 x 68 x 30 mm 7 6 x 2 6 x 1 2 inch Probe 198 x 25 x 19 mm 7 8 x 1 0 x 0 7 inch Accessories Inst...

Page 6: ...Button 3 6 Mode Button DC AC Button SET Button 3 7 Input socket 3 8 Probe Handle 3 9 Probe Sensing Head 3 10 Probe Plug 3 11 Probe Head Cover 3 12 RS 232 Output Terminal 3 13 Reset button 3 14 DC 9V P...

Page 7: ...0 0 mT c1 0 G c2 0 AC 0 AC 0 0 mT d1 0 G d2 0 AC 0 AC Note a1 screen is ready for DC 0 1 mT resolution measurement b1 screen is ready for DC 0 01 mT resolution measurement c1 screen is ready for AC 0...

Page 8: ...ic field measurement Display will show AC indicator Display will not show N S indicator 4 unit selection How to select the unit mG uT the procedures please refer to chapter 5 1 Change the unit mT G pa...

Page 9: ...nment magnetic field value 4 2 Data Hold During the measurement press the Hold Button 3 3 Fig 1 once will hold the measured value the LCD will display a HOLD symbol Press the Hold Button once again wi...

Page 10: ...easurement and execute the RECORD function it can not change from the North pole to South pole or from the South pole to North pole during the measurement It can make the measurement under the same po...

Page 11: ...After select the desiring function YES or no press the REC Button 3 4 Fig 1 to save the function with default 5 2 Select the measurement unit to mT or G When the lower display show unit 1 Use the REC...

Page 12: ...ia a 3 5 mm terminal 3 12 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232 lead with the following connection will be required to link the instr...

Page 13: ...0 Parity No parity Data bit no 8 Data bits Stop bit 1 Stop bit 7 BATTERY REPLACEMENT 1 When the left corner of LCD display show it is necessary to replace the battery However in spec measurement may s...

Page 14: ...make the system RESET will fix the problem The system RESET procedures will be either following method During the power on use a pin to press the Reset Button 3 13 Fig 1 once a while will rest the cir...