background image

Summary of Contents for AM-4214SD

Page 1: ......

Page 2: ...ment 8 4 3 Type K J thermometer 10 4 4 Data Hold 11 4 5 Data Record Max Min reading 11 4 6 LCD Backlight ON OFF 12 5 DATALOGGER 12 5 1 Preparation before execute datalogger function 12 5 2 Auto Datalo...

Page 3: ...position location No position 1 to position 99 Innovation and easy operation computer is not need to setup extra software after execute datalogger just take away the SD card from the meter and plug i...

Page 4: ...cessor LSI circuit Display LCD size 52 mm x 38 mm LCD with green backlight ON OFF Measurement Air velocity Unit m s meters per second Km h kilometers per hour Ft min FPM feet per minute Knots nautical...

Page 5: ...nt of SD card setting Auto power OFF management Set beep Sound ON OFF Set thermometer type to Type K or Type J Set temperature unit to or Set sampling time SD memory card Format Temperature Automatic...

Page 6: ...mA When SD card save the data and LCD Backlight is OFF Approx DC 50 mA Weight 515 g 1 13 LB Dimension Main instrument 203 x 76 x 38 mm Telescope Probe Round 12 mm Dia x 280 mm min length Round 12 mm...

Page 7: ...t 20 ft min Note m s meters per second km h kilometers per hour ft min feet per minute knot nautical miles per hour mile h miles per hour international knot Air temperature Measuring Range 0 to 50 32...

Page 8: ...Button Time check Button 3 6 Logger Button Button Sampling time check Button 3 7 Probe input socket 3 8 Type K J thermometer socket 3 9 SD card socket 3 10 RS 232 Output Terminal 3 11 Reset Button 3...

Page 9: ...er can select 2 kind function as a Air velocity Temp d Type K J Thermometer Pressing the Function Button 3 3 Fig 1 continuously not release the button the Display will show the following text in seque...

Page 10: ...r cover should slide to the up position Fig 2 Probe Handle When begin to use the probe a Slide the sensor cover to the down position let the air velocity sensor to contact the air refer Fig 3 b Extent...

Page 11: ...elocity value The lower display will show the temperature value Direction mark should face the measured wind sensor head side view Fig 4 Probe Handle 2 Function select to Air velocity Temp measurement...

Page 12: ...ct unit will save into the memory with default Change the temperature unit The meter Temp display unit is defaulted to If intend to let the meter s temperature unit default to then please refer chapte...

Page 13: ...n the display 2 With the REC symbol on the display a Press the REC Button 3 4 Fig 1 once the REC MAX symbol along with the maximum value will appear on the display If intend to delete the maximum valu...

Page 14: ...at If SD card just the first time use into the meter it recommend to make the SD card Format at first please refer chapter 7 8 page 21 It recommend strongly do not use memory cards that have been form...

Page 15: ...nable refer to Chapter 7 4 page 20 b Pause the datalogger During execute the Datalogger function if press the Logger Button 3 6 Fig 1 once will pause the Datalogger function stop to save the measuring...

Page 16: ...5 Fig 1 the lower no position no will flashing It can use the Button 3 6 Fig 1 or Button 3 5 Fig 1 to set the measuring position 1 to 99 for example room 1 to room 99 to identify the measurement loca...

Page 17: ...erate a folder AHA01 2 If the first time to execute the Datalogger under the route AHA01 will generate a new file name AHA01001 XLS After exist the Datalogger then execute again the data will save to...

Page 18: ...SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name AHA01001...

Page 19: ...e Next Button 3 3 Fig 1 once a while in sequence to select the eight main function the lower display will show dAtE Set clock time Year Month Date Hour Minute Second dEC Set SD card Decimal character...

Page 20: ...st the value Setting start from Year value After the desired value is set press the Enter Button 3 4 Fig 1 once will going to next value adjustment for example first setting value is Year then next to...

Page 21: ...er value to bASIC or Euro bASIC Use as the Decimal point with default Euro Use as the Decimal point with default 2 After select the upper text to bASIC or Euro press the Enter Button 3 4 Fig 1 will sa...

Page 22: ...N 2 After select the upper text to yES or no press the Enter Button 3 4 Fig 1 will save the setting function with default 7 5 Select the Thermometer to Type K or Type J When the lower display show tYP...

Page 23: ...7 Set sampling time SecondS When the lower display show SP t 1 Use the Button 3 6 Fig 1 or Button 3 5 Fig 1 to adjust the value 1 2 5 10 30 60 120 300 600 1800 3600 seconds 2 After teh Sampling value...

Page 24: ...nput Socket 3 12 Fig 1 The meter will permanent power ON when use the DC ADAPTER power supply The power Button function is disable 9 BATTERY REPLACEMENT 1 When the left corner of LCD display show it i...

Page 25: ...method During the power on use a pin to press the Reset Button 3 11 Fig 1 once a while will reset the circuit system 11 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5...

Page 26: ...ates the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right to the left 0 No...

Page 27: ...ra fast response naked bead thermocouple suitable for many general purpose application Thermocouple Measure Range 50 to 900 Probe 58 to 1650 Type K TP 02A Dimension 12cm tube 3 2mm Dia Thermocouple Me...

Page 28: ...er SD card structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 TAIWAN M 358970 M 359043 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 USA P...