7 Transporting transformer to the operating site
Maschinenfabrik Reinhausen GmbH 2015
168
4427410/00 EN
OILTAP® R
Transporting transformer to the operating site
WARNING
Danger of death or severe injury!
Danger of death or severe injury from explosive gases under the on-load
tap-changer head cover, in the pipework system, in the oil conservator or at
the dehydrating breather opening!
► Ensure that there are no naked flames, hot surfaces or sparks (for ex-
ample caused by static charging) in the immediate surroundings and
that none occur.
Transport with removed drive
If you have to remove the drive to transport the transformer, proceed as fol-
lows:
1.
Ensure that the drive and the on-load tap-changer are in the adjustment
position.
2.
Remove the drive.
3.
Do not actuate drive while on-load tap-changer is not coupled and do
not turn output shaft.
4.
Do not actuate an on-load tap-changer which is not coupled and do not
turn its drive shaft.
5.
Transport drive to installation site in the MR delivery packaging.
6.
Fit drive and drive shaft to transformer at the operating site (see page
[
Transport with oil fill and without oil conservator
If the transformer is filled with oil but stored or transported without an oil con-
servator, a connecting lead for pressure compensation must be installed be-
tween the interior of the compartment and the transformer tank's oil cham-
ber.
To do so, proceed as follows:
► Establish the connecting lead on the on-load tap-changer head between
connections E2 and Q or E2 and R.
Figure 215: Connecting lead
7
7.1
7.2