5 Mounting
Maschinenfabrik Reinhausen GmbH 2021
34
8209941/00 EN
ECOTAP
®
VPD
®
III 30D-24 / MD&C
4. Also check the position of the shaft of the on-load tap-changer: If the pre-
vious on-load tap-change operation has been finished correctly, the arrow
on the cam disk
will point to the arrow in the cover
.
Figure 11: Position of the shaft of the on-load tap-changer
ð
If the shaft of the on-load tap-changer is in this position, the on-load
tap-changer is in a defined operating position. If this is not the case,
correct the position as described below.
5.
NOTICE!
Only use the emergency drive shaft built into the sealing mod-
ule. Failure to do so can result in damage to the on-load tap-changer.
6. Pull the emergency drive shaft out of the bracket in the sealing module.
Figure 12: Removing emergency drive shaft