mr. steam Linear Steam Head 104216 Installation Instructions Download Page 1

R E A D M E F I R S T !

As you follow these instructions, you will notice

warning and caution symbols. This information

is important for the proper, safe and trouble free
installation of the Linear Steam Head. These are
types of potential hazards that may occur if in-
stallation instructions are not carefully followed.

This signals a situation where injury or property

damage may occur if you do not follow instructions.

IMPORTANT NOTE:

This highlights information that is espe-

cially relevant to a problem-free installation.
All information in these instructions is based on the

latest informa-

tion available at the time of publication. Sussman-Automatic Corpo-
ration reserves the right to make changes at any time without notice.

1

Linear Steam Head

®

mr

.

steam

®

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Installation Instructions

Model 104216

• Linear Steam Head model 104216 is suitable for MrSteam

generator models MS90 – MS400, MSSUPER1– MSSUPER3,
MX4 – MX6.
Do not use Linear Steam Head model 104216 for any other
MrSteam steam generator. Do not use the Linear Steam
Head with any steam generator that is not a MrSteam steam
generator. Failure to follow these instructions may result in a
leak within the wall cavity and cause problems associated
with leaks, moisture and property damage from leaks.

• Do not use the Linear Steam Head with any steam generator

that

 

is

 

not

 

a

 

MrSteam

 

steam

 

generator.

 

Do

 

not

 

locate

 

the

 

steam

 

head

 

in

 

any

 

location

 

where

 

the

 

steam

 

emission

 

zone

 

is

 

near

 

a

 

seat,

 

bench

 

or

 

any

 

space

 

occupied

 

by

 

any

 

persons.

 

Failure

 

to

 

follow

 

these

 

instructions

 

may

 

result

 

in

 

a

 

hazardous

 

condition,

 

scalding

 

or

 

personal

 

injury.

Using

 

model

 

104216

 

for

 

any

 

steam

 

generator

 

model

 

larger

 

than

 

the

 

MX6,

 

or

 

for

 

any

 

non

 

MrSteam

 

brand

 

generators

 

may

 

result

 

in

 

an

 

improper

 

installation

 

or

 

hazardous

 

condition.

• Do

 

not

 

use

 

the

 

Linear

 

Steam

 

Head

 

with

 

any

 

NON-MrSteam

equipment

 

or

 

devices,

 

including

 

but

 

not

 

limited

 

to

 

water

 

softeners,

 

steam

 

generators,

 

etc.

 

Using

 

the

 

Linear

 

Steam

 

Head

 

with

 

any

 

NON-MrSteam

 

equipment

 

or

 

devices

 

may

 

result

 

in

 

personal

 

injury

 

or,

 

Linear

 

Steam

 

Head

 

damage

 

or

 

property

 

damage.

• MrSteam

 

steam

 

generators

 

Models

 

MX4,

 

MX5

 

and

 

MX6

require

 

two

 

104216

 

steam

 

heads.

 

Failure

 

to

 

use

 

two

 

steam

 

heads

 

may

 

result

 

in

 

steam

 

head

 

operation

 

where

 

incidental

 

contact

 

by

 

the

 

bather

 

with

 

direct

 

steam

 

emission

 

may

 

occur.

 

Do

 

not

 

locate

 

the

 

steam

 

head

 

in

 

any

 

location

 

where

 

the

 

steam

 

emission

 

zone

 

is

 

near

 

a

 

seat,

 

bench

 

or

 

any

 

space

 

occupied

 

by

 

any

 

persons.

 

Failure

 

to

 

follow

 

these

 

instructions

 

may

 

result

 

in

 

a

 

hazardous

 

condition,

 

scalding

 

or

 

personal

 

injury.

CAUTIONS

!

• Because the steam head and direct steam emission

are very hot, locate the steam head where incidental
contact by the user with the steam head or direct
steam emission cannot occur.

• Model 104216 Linear Steam Heads are for residential

use only. Do not use Model 104216 Linear Steam
Heads for commercial installations, Day Spa, or with
commercial steam generators. Using Model 104216
Linear Steam Heads for commercial, Day Spa or
installations with commercial steam generators or any
installation with steam sessions exceeding 60 minutes
a day, may result in Linear Steam Head damage,
property damage or personal injury.

• Do not use any Linear Steam Head in any commercial

installation or with any commercial steam generator.
Using any Linear Steam Head in a commercial
installation or with any commercial steam generator
may result in Linear Steam Head damage, property
damage or personal injury.

• Install in a horizontal orientation only. Installation in a

non-horizontal orientation may concentrate the steam
and result in excessive temperatures. Failure to install
in a horizontal orientation may result in steam head
operation where incidental contact by the bather with
direct steam emission may occur. Failure to follow
these instructions may result in a hazardous condition,
scalding or personal injury.

• Insulate the steam head and piping as required to

reduce temperatures within the wall cavity. Do not
locate the steam head or plumbing near any materials,
including wiring, devices, or products that may be
adversely affected by elevated temperatures. Failure
to follow these instructions may result in the failure of
materials, including wiring, devices, or products.

(continued on next page

CAUTION

!

100561-1

 

Rev

 

3.20

.

1

mr.steam

®

Sussman-Automatic Corp®

[email protected] www.mrsteam.com

43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM

9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM