SPECIFICATIONS
Table 1. Specifications (DEF Tank)
Model
DEFTANK1
DEFTANK2
System Voltage
Requirement
12 VDC
Amperage Requirement
5.0 amps
5.0 amps × 2
Flow Rate
0.75 gpm (2.83 lpm)
0.75 gpm (2.83 lpm) × 2
Maximum Fluid Pressure
5 psi (34.4 kPa)
External Hose Length
25 ft. (7.62 m)
25 ft. (7.62 m) × 2
Communication
Cable Length
25 ft. (7.62 m)
25 ft. (7.62 m) × 2
Controller Type
Parker
Tank Capacity
100 gallons (379 liters)
Tank Material
Polyethylene
DEF Fluid Type
Complies with ISO-2224
Optional Heater Receptacle
120 VAC @1,500 watts
Dry Weight
1,210 lb. (548.8 kg)
Wet Weight
2,110 lb. (957.1 kg)
Table 2. Specifications (DEF Dispenser Kit)
Model
DEFDISPENSERKIT
DEF Flow
8 gpm (30.28 lpm)
Nozzle Size
3/4 in. (19 mm)
Maximum Pressure
38 psi (262 kPa)
Motor Amperage
22 amps
Motor Voltage
12 VDC
Pump Motor
1/4 hp
Duty Cycle
30 minutes
Hose Length
20 ft. (6.09 m)
Material
Poly laminated stainless steel
Weight
17 lb. (7.71 kg)