MPP Solar PCM4048 User Manual Download Page 1

 

Table of Contents 

IMPORTANT NOTES ....................................................................................... 2

 

1.0

 

I

NTRODUCTION

 ..................................................................... 3 

1.1

 

I

NSTALLATION 

S

ITE

 ................................................................ 4 

1.3

 

A

CCESSORIES

 ........................................................................ 7 

1.4

 

LED

 

I

NDICATION 

E

XPLANATIONS

 ............................................... 7 

2.0

 

LCD

 

D

ESCRIPTION

 ................................................................. 8 

2.1

 

O

PERATION

 ......................................................................... 9 

2.1.1Enter into Setting Mode ................................................................................. 11

 

2.1.2Battery Capacity(AH) Setting ......................................................................... 12

 

2.1.3Battery Voltage Setting ................................................................................. 12

 

2.1.4 Battery Over-voltage Limit Setting ................................................................ 13

 

2.1.5 Battery Under-Voltage Limit Setting ............................................................. 14

 

2.1.6 Pulse Charge Setting ..................................................................................... 14

 

2.1.7 Parallel Address Setting ................................................................................ 15

 

2.1.8 Total Input Power(KWH)Setting: ................................................................... 15

 

2.1.9 Parameters Displayed ................................................................................... 16

 

2.2

 

LCD

 

D

ISPLAY 

E

XPLANATIONS

 ..................................................16 

2.3

 

E

RROR 

C

ODES

 .....................................................................18 

3.0

 

P

RODUCT 

S

PECIFICATIONS

 ......................................................19 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for PCM4048

Page 1: ...etting Mode 11 2 1 2Battery Capacity AH Setting 12 2 1 3Battery Voltage Setting 12 2 1 4 Battery Over voltage Limit Setting 13 2 1 5 Battery Under Voltage Limit Setting 14 2 1 6 Pulse Charge Setting 1...

Page 2: ...y authorized technician may repair or replace the interior components 5 Make sure the ground of the load is connected properly Otherwise you may get electrical shock 6 Keep the PV charger clean and dr...

Page 3: ...charger Figure 1 The front view of the solar charger Standard features of the solar Charger Maximum Power Point Tracking MPPT maximizes energy harvest from the PV array Auto selection Four stage Bulk...

Page 4: ...s damage occurred The packaging is recyclable save it for reuse or dispose of it properly 2 It is designed to be installed and commissioned in a sheltered controlled environment as follows Operating t...

Page 5: ...00 FROM PV ONLY THEREFORE AT NIGHT TIME OR UNDER LOW LIGHT CONDITIONS WHERE PV VOLTAGE IS INSUFFICIENT THE UNIT WILL POWER OFF THIS IS NORMAL ONCE PV VOLTAGE REACHES THE THRESHOLD SEE ABOVE UNIT WILL...

Page 6: ...tage via LCD panel is required to be set Charging Mode Output connecting battery or connecting both battery and load Output voltage via LCD panel can be fixed or auto set Caution 1 Make sure all cable...

Page 7: ...3 Connecting terminal to the solar panel phi4 female 1 1 4 LED Indication Explanations Figure 6 Bottom View LED Description Fault Red System Fault Protection Circuit is activated PV Low Amber Under v...

Page 8: ...to Protection Mode Error code shown on the LCD 2 Under voltage Over voltage of Solar Cell 3 Charging Mode Illuminate Load Mode Flash 4 Function Key Left push slightly Return push heavily 5 Scroll Key...

Page 9: ...rawing C then the green LED lights up to indicate that the charger is connected with batteries and also charges to the batteries On the contrary it shows that there are no batteries connected when the...

Page 10: ...ther parameters you may press key or key Caution keys are of no use You may press or key to scroll up and down to get different display information and message Display Description Battery Voltage VDC...

Page 11: ...y see the three LEDs on the front panel will light up and extinguish after 3 second Then AH text will be indicated on the LCD display which means the charger is in setting mode now If no AH text shown...

Page 12: ...elected please press key to save till SAVE shown on the screen When SAVE disappears on the screen it means your setting is done successfully Step4 To escape from Battery Capacity AH setting please pre...

Page 13: ...hin window For example if the user selects 24V the default over voltage is 27 3V In case the battery voltage desired is higher than this voltage you may calibrate battery voltage to be higher Maximum...

Page 14: ...oose the figure you prefer The figure with blinking means the current place you are To change the figure at left hand side please press key on the contrary you may press key to change the right hand s...

Page 15: ...r details on how to employ the parallel address features please consult your network engineer When there are several chargers in parallel you may proceed the setting as below Step1 Enter to Parallel A...

Page 16: ...999K KWH Once the figure is selected you may press key to save Make sure the SAVE shown on the screen then you may release key now When SAVE disappears on the screen it means your save is done success...

Page 17: ...y Temperature in Celsius IGBT temperature in Celsius Battery Temperature in Fahrenheit IGBT temperature in Fahrenheit Battery Capacity Setting Directory Battery Voltage Setting Directory Battery Over...

Page 18: ...the ambient temperature and reduce load connected ER25 Input Over current Decrease solar power Watt or reduce load connected ER28 Output Voltage too high Re start the charger ER32 Memory Error Re sta...

Page 19: ...oltage setting table etc Status on LED Normal Fault PV Low Protection Overload 110 shutdown 105 shutdown Short Circuit at load side Output current 60A shutdown Solar Cell Polarity Error Protection Yes...

Reviews: