Quick start Manual PIRS 

 

 
 
 
 

 

 

 
 

Quick Start Manual 

 

PIRS 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Quick start Manual Version: 1.1 
Updated to the Software Version: 1.0.0 
Updated to Firmware Version: 1.01 

 
 

 

Summary of Contents for PIRS

Page 1: ...131 Rome Italy Tel 39 0641200744 Fax 39 0641200653 info gruppompb com www gruppompb uk com Quick start Manual PIRS Quick Start Manual PIRS Quick start Manual Version 1 1 Updated to the Software Version 1 0 0 Updated to Firmware Version 1 01 ...

Page 2: ...onditions that fully comply with European standards To ensure the correct use of the product these general instructions must be read and applied before and for any use of the instrumentation The PIRS is made for industrial environments and should be used by authorized staff only MPB disclaims any responsibility for a use of the device different from explained in the manual In order to keep the 24 ...

Page 3: ...ing European standards Safety EN 61010 1 undated reference applies to all editions EMC emissions EN 61326 1 undated reference applies to all editions EMC immunity EN 61326 1 undated reference applies to all editions This product complies also with the 2014 35 CE Low voltage directive requirements and with 2014 30 EU Electromagnetic compatibility and with R0HS 2011 65 EU MPB S r l ...

Page 4: ...k diagram 7 2 2 Working principles of PIRS 7 3 Software 8 3 1 Installation 8 3 2 Connecting the instrument 10 3 3 New list creation 11 3 4 Edit list 11 3 5 Delete list 11 3 6 Delete frequency 11 3 7 Add frequency 12 3 8 Delete all frequency from list 12 3 9 Wizard table 12 4 Calibration 13 4 1 General 13 4 2 Quiet zone pre saved 13 4 3 Quiet zone with sample probe 13 5 Measures 14 5 1 setup 15 Tur...

Page 5: ... the electric fields with intensity among 1 V m and 30 V m inside shielding rooms TEM and GTEM Cells anechoic and semi anechoic chambers Thanks to its batteries power supply and its 8 hours autonomy in generation and continuous power amplification it can be used with extreme ease in any environment mostly in Situ to perform Radiated Immunity Test on high dimensions devices hardly to transport insi...

Page 6: ...ting Temperature 10 40 C Certificate of Calibration Standard LAT Dimensions 30 x 15 x 8 cm Weight 1 7 kg Power 8 batteries 18650 rechargeable and replaceable by the operator Custom list From 128 to 500 points each Auto calibration Set point Feedback tolerance With sample probe or with mathematical model Configurable for each list via software Minimum user defined 2 5 Typ 5 Feedback With sample pro...

Page 7: ...ying out the proper calibration using a sample probe see cap 4Calibration it is possible to create at selected frequencies a table of power that the PIRS must generate in order to have a target filed chose by the operator The field generated will be a function of the distance of the object to be radiated the type of antenna and the environment By the PIRS the operator creates a quite field area in...

Page 8: ...ware 3 1 Installation Launch the setup file setup exe and eventually click YES Execute in the pop up window Please note that the PIRS SW can require to be executed as administrator Follow the steps as in the following figures Figure 3 ...

Page 9: ...QUICK START MANUAL PIRS 9 Figure 4 Figure 5 ...

Page 10: ...necting the instrument 1 Start the PIRS Software connect the USB cable to the computer and to the instrument at the first connection wait for the driver installation at the end of which a notification of the operating system will appear Figure 7 ...

Page 11: ...set point 6 Set the duration of the signal generation 7 Click Add row to insert a new frequency list 8 Click Send to PIRS to save the list in the instrument 3 4 Edit list To modify a frequency list double click on the list in the frequency list box and change the parameters in the right panel called List number 3 5 Delete list To delete a list selects it in the frequency list box and click on the ...

Page 12: ...e all frequency from list To delete all frequency list click on the clear all button 3 9 Wizard table Figure 9 This tool allows you to create a new frequency list by entering The start frequency The stop frequency The list type Linear logarithmic percentage etc Click on create to return to the previous window and create the list frequencies ...

Page 13: ...osen setting For this compilation process it is essential to use a meter that reads the filed level of a sample probe 4 2 Quiet zone pre saved The calibration lists are already saved in the instrument The calibration is carried out by MPB according to the customer s requests With these configurations the operator only needs to reproduce the same calibration setup and perform the measurement as sho...

Page 14: ...PIRS Connect the optical fiber Turn on the meter Press the button CAL F3 of the PIRS Press the button List F4 and select the desired pre located frequency list see chapter 3 3 Press Enter F4 to select Press Start F2 to calibrate and wait until the end of the procedure 5 Measures Now after the calibration the PIRS can generate the choose field Place the object to be irradiated in the position in wh...

Page 15: ...to maintain exactly the same positioning of the various elements as in the previous step of calibration see chapter 4 Turn on the PIRS Press button GEN F2 Press button LIST F4 With UP F2 and Down F3 choose the list and press ENTER F4 Press START F2 to begin with the field generation Wait until the process is finished ...

Page 16: ...QUICK START MANUAL PIRS 16 Further information www gruppompb uk com Technical information assistenza gruppompb com Phone 39 06 41200744 ...