CLEANING SPIN FILTER DISCHARGE APEX ORIFICE:
Depending on the application and debris load, particles or layers of debris may build up
causing the discharge apex of the spin filter to clog and not properly deposit the
concentrated slurry into the settling tank. Cleaning is quick and easy.
1. Turn CDR system off by pressing button 9, then turning off all power with
disconnect.
2. Allow system 1-2 minutes for fluid to drain out of spin filters.
3. Using a rag in hand, unthread the bottom nut to remove the ceramic apex cone,
being careful not to damage or lose o-ring.
4.
Use a nylon bore brush, carefully clean out the ¼” apex opening to remove any
debris that may be built up.
5. Reinstall filter cone, ensuring o-ring is properly seated, onto the spin filter. Hand
tighten with rag.
6. Turn system back on, let pressure stabilize, and visually inspect the discharge skirt,
making shirt there is an even ring of fluid around the edges.
REPLACING WORN HYDRO CYCLONES:
Depending on the abrasive nature of the particles going through the filters, they may wear
down over time and need to be replaced. The filters are assembled from modular parts
that can be replaced as needed. Contact MP Systems for more information and to
purchase replacement components.
9.
Spare Parts
Part
Part Number #
Y Strainer Screen
– 12 Mesh
HF 2” STRAINER SCREEN 12M
Y Strainer O-Ring
M ORING .188 X 3.250 75A
“SD” Perforated Filter Basket
HF FILTER BASKET 1/16
” PERF #1
“SD” Filter Vessel O-Ring
M ORING MPA
Hydro-Cyclone Inlet Chamber
SF EN65 FEED CHAMBER
Hydro-Cyclone Main Cone
SF EN65 CONE
Hydro-Cyclone Ceramic Cone Assembly
SF APEX ASSY
Hydro-Cyclone Inlet-Cone O-Ring
M ORING .125 X 2.25 75A
Hydro-Cyclone Ceramic Cone O-Ring
M ORING .062 X 1.000 75A
5 Gallon Bucket Black
SH BUCKET - 5 GALLON BLACK