background image

User 

manual

THERMAEGH

      English      V1.2

Instruction

The 

THERMAEGH

 thermostat control

s

 the floor heating system based on built-in weekly program. The 

weekly program runs in 4 or 2 stages per day, 7 days a week. The default weekly program parameters 
can satisfy most usage scenarios. If your living habits are different, you can also modify the weekly 
program parameters in the thermostat or APP. When there is no one in the house, it is recommended 
to set the temperature down to save energy. Besides, the thermostat has built-in adaptive function. 
When this function acts, the thermostat heats or stops heating in advance of next stage to bring the 
room temperature to the set temperature of the next stage. Please note that after turning adaptive on, 
the thermostat takes a few days to learn the time required.

Installation

 

To avoid risk of electric shock, disconnect all power coming to

heater at main service panel before installation of the thermostat. Keep air vents of thermostat clean

and free from obstructions. All wiring must conform to local and national electrical codes and 

ordinances. Installation must be carried out by qualified personnel.  

WARNINGS

Classification

The thermostat is a Class II device (reinforced insulation) and used for controlling electrical floor 

heating. The product must be connected to the following leads:

L/N lead: Connect the power cord using the terminal block.

L1/N1 lead: Use a terminal block to connect the load line(Max 15A).

Note:

Electric floor heating cable/mat must be in accordance with the supply voltage.

The terminals are designed to handle a cross-section of wire measuring 12-22AWG. 

Technical specification

             

Supply voltage:          120/240 VAC 50/60 Hz

Load: 

  max.15 A (resistive load)

GFCI: 

            Class A (5 mA trip level)            Setpoint range:     +5 to +40°C / +41 to +104°F

Temperature range:   +5 to +45°C / +41 to +113°F 

unscrew it.
2. Wire as shown:

L/N lead:

 Connect the power cord using the terminal block.

L1/N1 lead:

 Use a terminal block to connect the load line.

IN/SNR terminal:

 Connect the floor sensor.

OUT terminal: 

Connect to IN/SNR of Power Module.

Note: Disconnect the main power supply before wiring.

If an electric floor heating cable or mat system requires more than 15 Amps, install a power module.

Wiring diameter: 12 to 22 AWG.

3. Install the back

 cover into the

 terminal box and

 secure it with

 the set screw.

4. Fit the left side of the front and rear covers as shown.Rotate to

the right again and press the upper half of the right 

border until you hear a click. Use a screwdriver to 

secure the bottom screw. Turn on the power and 

test the GFCI function.

Symbols

Ground Fault Circuit Interrupter (GFCI)

This thermostat has a built-in GFCI function that protects people from electric shock. It is very 
important to check whether the GFCI function is normal or not every month. Here are the check 
steps:
1. Confirm that the thermostat is turned on.

4. Press the [Reset] button again. The thermostat is turned on.
If in daily use, the red light is on and the screen appears GROUND FAULT. Then you need to 
check if the ground fault is present by pressing the [Reset] button. If the red light is off and the 
screen shows the shutdown status, it is nuisance tripping. If not, it means that ground fault has
occurred. Please contact your dealer or professional technician immediately.

2. Press the [Test Monthly] button. If a red light appears in the upper left corner of the 
thermostat and GROUND FAULT appears on the screen, the GFCI function is normal. If there is
no response, it means the function is invalid, please contact the dealer or electrical installer.
Note: Do not press and hold the [Test Monthly] button.
3. Press the [Reset] button. The red light is off and the screen shows the power off state.

WiFi connection(Only for 

THERMAEGH

)

Step 1:

 Scan the QR code or download Warmme from APP store/Google browser. 

Step 3: 

Click ‘Add Device’ or ‘+’ on the top-right to add device.

 

Step 4: 

Click ‘WiFi thermostat’.

Step 5:

    Operate thermostat. If the WIFI icon flash quickly, 

    Click ‘Press to connect’. 

Step 6:

 Enter Wifi password, and click ‘Confirm’.

Step 7: 

If device added successfully, you can change the device name and set region,

then, click ‘Done’. 
Attention: If failed, please confirm the Wifi is 2.4G version and check the Wifi

signals, then, use the ‘AP mode’ in the top right to connect again.  

Step 8: 

You can check the real-time temperature and set temperature etc. at the control

interface. 

Functions and operation

On/Off

The GFCI Reset button is also the switch button. Press the [Reset] button to switch on and off.

Temporary Override Temperature

This function is enabled in the automatic intelligent mode, when the temperature demand changes 

at this moment, the setting temperature is enabled, but the parameters in the Event are not 

changed.

Operation method:

Under the interface showing the real-time temperature, tap

 ▲ 

or

 ▼ t

o modify the set temperature.

Tap 

OK

 to confirm and return to the interface showing the real-time temperature.

Mode selection

This thermostat provides three operating modes:

How to set the mode selection:

In the interface displaying the real-time temperature, tap 

OK

 to enter the first level menu, and 

Mode is flashing.

Tap 

OK

 to enter the mode selection.

Tap

 ▲ 

or

 ▼ t

o change the mode.

Tap 

OK

 to confirm your selection.

If you select manual mode or freeze protection mode, you also need to tap

 ▲ 

or

 ▼ t

o set the 

temperature.

Tap 

OK

 to return to the interface showing the real-time temperature.

The thermostat provides a key lock function to prevent the thermostat setting parameters from 

being incorrectly modified.

Note: the [Reset] button and the [Test Monthly] button can still operate normally so as to response 

to an emergency.

Key lock

Set the key lock mode:

1. Under real-time temperature interface, press and hold     until the lock symbol appears.

2. Under real-time temperature interface, tap 

OK

 to enter the first level menu, and Mode is

flashing.

Tap

 ▲ 

or

 ▼ t

o select Key Lock.

Tap 

OK

 to enter the key lock setting.

Tap 

OK

 to confirm.

Tap 

OK

 to return to the interface showing the real-time temperature.

Cancel the key lock mode:

Under real-time temperature interface, press and hold     until the lock mark on the screen 

disappears.

Automatic mode: 

According to the weekly program, the thermostat automatically adjusts the set 

temperature operation.

Manual mode: 

The thermostat runs continuously according to the set temperature.

Frost protection mode:

 The temperature controller runs at a lower set temperature. The temperature 

range is set from 41°F to 59°F in this mode. This mode is used when you want to keep your room at a 

lower temperature when you are on vacation.  

Weekly program parameter setting

In the automatic mode, the thermostat runs automatically according to the setting parameters of the 

weekly program. The weekly program parameters contain two parameters: Schedule and Event.

1. Schedule

Assign seven days a week to the following two schedules:

5+1+1:

 The Event parameter is the same from Monday to Friday, with separate Event parameters

on Saturday and Sunday.

7:

 With separate Event parameters every day.

Schedule parameter setting method:

Under real-time temperature interface, tap 

OK

 to enter the first level menu, and Mode is flashing.

Tap

 ▲ 

or

 ▼ t

o select Schedule.

Tap 

OK

 to enter the parameter settings.

Tap

 ▲ 

or

 ▼ t

o select a parameter.

Tap 

OK

 to confirm.

Tap 

OK

 to return to the real-time temperature interface.

2. Event

In the Home scenario, the day is divided into four events: Wake--     Leave--     Return--     Sleep--

(In the Office scene, the day is divided into two phases: on work--     off work--    ). The set 

temperature for each stage can be set separately.

Event default parameter list

Office

Home

Week

Mon--Fri

Sat--Sun

Week

Mon--Fri

Sat--Sun

Start time

8:00

8:30

69°F

79°F

Tempera-

ture

Leave

Return

Sleep

Start time

17:00

17:30

78°F

78°F

Tempera-

ture

Start time

22:00

22:00

69°F

69°F

Tempera-

ture

off-work

Wake

Start time

6:00

8:00

78°F

78°F

Tempera-

ture

on-work

Start time

7:00

7:00

78°F

68°F

Tempera-

ture

Start time

18:00

18:00

69°F

69°F

Tempera-

ture

Under real-time temperature interface, tap 

OK 

to enter the first level menu, and Mode is flashing.

Tap

 ▲ 

or

 ▼ t

o select Event.

Tap 

OK

 to enter the week selection.

Tap

 ▲ 

or

 ▼ t

o select the day you want to modify the parameters.

Tap 

OK

 to enter the stage selection for the day.

Tap

 ▲ 

or

 ▼ t

o select the stage that you want to modify the parameters.

Tap 

OK

 to enter the temperature setting of the current phase.

Tap

 ▲ 

or

 ▼ t

o select the temperature value you want to set.

Tap 

OK

 to enter the hour setting for the start time of the current phase.

Tap

 ▲ 

or

 ▼ t

o select the hour of the start time.

Tap 

OK

 to enter the minute setting for the start time of the current phase.

Event parameter setting method:

 

Settings

In addition to the above common functions, the thermostat also provides a number of settings for 

more occasions. It should be noted that such settings need to be set by professional technicians 

to avoid damage caused by abnormal settings.

Settings access method:

Under real-time temperature interface, tap 

OK

 to enter the first level menu, and Mode is flashing.

Tap

 ▲ 

or

 ▼ t

o select Settings.

Tap 

OK

 to enter Settings.

Settings contains the following items:

1.Time

Set the current real time and day of the week.

Note: The WiFi version of the thermostat will automatically update to local time after networking.

Time setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Time.

Tap 

OK

 to enter the hour setting for the time.

Tap

 ▲ 

or

 ▼ t

o select the hour value for the current time.

Tap 

OK

 to enter the minute setting for the time.

Tap

 ▲ 

or

 ▼ t

o select the minute value for the current time.

Tap 

OK

 to enter the day of the week setting.

Tap

 ▲ 

or

 ▼ t

o select the day of the week.

Tap 

OK

 to enter the hour setting for the time.

Tap      multi times to return to the real-time temperature interface.

2. Temp unit

°F or °C can be selected as the temperature unit.

Temp Unit setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select °F/°C.

Tap 

OK

 to enter the selection.

Tap

 ▲ 

or

 ▼ t

o select the desired temperature unit.

Tap 

OK

 to confirm.

Tap 

OK

 to return to the real-time temperature interface.

No.

Sensor Type

Parameters

00

01

02

3950(default)

3600

3700

R(25°C)=12kΩ   R(10°C)=22.2kΩ

R(25°C)=10kΩ   R(10°C)=19.1kΩ

4.Sensor selection

In addition to the floor sensor, this thermostat has built-in sensors to detect room temperature.

Therefore, three sensor applications are available:

Room:

 Controls room temperature based solely on built-in sensors.

Floor:

 Controls the floor temperature based solely on the floor sensor.

Room.Limit:

 Controls the room temperature based on the built-in sensor while monitoring the floor 

temperature not to exceed the upper limit. This application, like Floor, can be used in places such as 

wood floors where floor temperature is critical.

Sensor Selection setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Sensor Selection

.

Tap 

OK

 to enter the selection.

Tap

 ▲ 

or

 ▼ t

o select the sensor application type.

Tap 

OK

 to confirm.

Tap 

OK

 to return to the real-time temperature interface.

Note: If Room.Limit is selected, you need to set the maximum temperature that the floor can accept.

5. Calibration

This thermostat has built-in probe and floor sensor calibration function. In the case of demand for 

higher precision

Calibration setting method:

After entering Settings , tap

 ▲ 

or

 ▼ t

o select Calibration

.

commonly used floor sensors. When replacing the old thermostat, there is no need to replace the

floor sensor for easy installation.

Sensor Type setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Sensor Type.

Tap 

OK

 to enter the selection.

Tap

 ▲ 

or

 ▼ t

o select the type of floor sensor you are currently using.

Tap 

OK

 to confirm.

Tap 

OK

 to return to the real-time temperature interface.

3.Sensor type

This thermostat can be connected not only to the floor sensor but also to two other

Tap 

OK

 to go to select Room

 or 

Floor

.

Tap

 ▲ 

or

 ▼ t

o select Compensate Built-in Probe or Floor Sensor.

Tap 

OK

 to enter the compensation setting.

Tap

 ▲ 

or

 ▼ t

o adjust the real-time temperature to match the displayed temperature value of the

calibration instrument.

Tap

 OK

 to return to the setting item selection.

6. Location

This thermostat is suitable for use in both homes and offices. For the office, a set of weekly

program parameters is built in. See the Weekly Program Parameters section for details.

Location setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Location.

Tap 

OK

 to go to select Office or Home.

Tap

 ▲ 

or

 ▼ t

o select one.

Tap 

OK

 to confirm.

Tap 

OK

 to return to the real-time temperature interface.

7.Adaptive

This thermostat has an adaptive function. When this function is enabled, the thermostat heats up or

stops heating in advance so that the next stage comes and the temperature just reaches the set 

temperature.

E1: Built-in probe failure, please contact your dealer or professional technician.

E2: External probe failure, please contact your dealer or professional technicia

Troubleshooting

Tap 

OK

 to confirm.

Tap 

OK

 to return to the real-time temperature interface.

8.Readout

This thermostat has the function of calculating the percentage of heating time over a period of time.

The relevant parameters can be queried through the Readout item.

Readout query method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Readout.

Tap 

OK

  to enter the selection. 

Tap

 ▲ 

or

 ▼ t

o select 1Day, 30Days or 365Days to query. 

Tap 

OK

 to return to the setting item selection. 

9.Factory reset

This thermostat has the function of restoring factory parameters.

Factory Reset setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Factory Reset.

Tap 

OK

 to enter the selection. 

Tap

 ▲ 

or

 ▼ t

o select Yes or No.

Tap 

OK

 to confirm. 

Tap 

OK

 to return to the real-time temperature interface. 

Dimension(Inch)

1 On/Off/GFCI reset button

2 GFCI test button

3 Mode

4 Temperature

5 Sensor selection

6 WiFi indicator

7 Setpoint

8 Event

9 Day and time

10 Touch key

1.Loosen the bottom screw by a Phillips screwdriver. Then

open the thermostat from the upper right side as shown.

Note: Screw the nut out of the groove and do not need to 

Step 2:

 Register and log in with mobile number

or email address in the APP.

Attention: Please read and agree “Privacy Policy 

and Service agreement” before registration.

Tap

 ▲ 

or

 ▼ t

o select the minute of the start time.

Tap 

OK

 to return to the stage selection for the day.

Note: Return to the interface of the real-time temperature and tap     multiple times.

Adaptive setting method:

After entering Settings, tap

 ▲ 

or

 ▼ t

o select Adaptive. 

Tap 

OK

 to enter the selection.

Press 

▲ 

or

 ▼ to get Yes or No.

Settings default parameter list

NO.

Name

Default Parameter

Setting Range

1

Time

/

/

2

°F/°C

°F

°F

°C

3

Sensor Type

00 3950

00 3950

01 3600

02 3700

4

Sensor Selection

Floor

Room

FLoor

Room.Limit

Calibration

0°F

-9°F -- 9°F

5

6

Location

Home

Home

Office

8

Readout

/

/

7

Adaptive

No

Yes

No

9

Factory Reset

No

Yes

No

Summary of Contents for THERMAEGH

Page 1: ...arameter Tap OK to confirm Tap OK to return to the real time temperature interface 2 Event In the Home scenario the day is divided into four events Wake Leave Return Sleep In the Office scene the day is divided into two phases on work off work The set temperature for each stage can be set separately Event default parameter list Office Home Week Mon Fri Sat Sun Week Mon Fri Sat Sun Start time 8 00 ...

Page 2: ...related account Smart devices 2 Add devices in Smart Life app Refer to App Instruction You can skip this part if you ve already add some devices to your Smart Life account and in the meantime the devices name are easily recognized 2 1 Download Smart Life app Refer to App Instruction You can scan the QR code below to download the Smart Life app You can also search Smart Life in either App Store or ...

Page 3: ...n skip this part if your Google Home is already set up 1 Make sure your Google Home is energized 2 Open the Google Home app by tapping the app icon on your mobile device 3 Tap ACCEPT to agree to the Terms of Service and Privacy Policy Allow Google Home app to access the device location to discover and set up nearby devices 4 Tap SIGN IN choose one Google account that you already logged in on your ...

Page 4: ...located This helps you identify the device when you want to cast to it Choose the Wi Fi network you want to connect to your Google Home To automatically fetch the password for this network on this device tap OK then the password will populate in the password field You can also manually enter your password Then tap CONTINUE 8 Google Home will now attempt to connect to the provided Wi Fi network Whe...

Page 5: ... want to link to your Google Home device then tap CONTINUE AS XXX Enter the address where this Google Home is installed and select your default music service 10 Tap SKIP TUTORIAL to finish the setup You can also tap CONTINUE to watch the Google Home tutorial 3 2 Link Smart Life account in Home Control 1 Tap Home Control in the hamburger menu on the Google Home app s home page then tap ...

Page 6: ...will be listed in the Home Control page 4 Control your smart devices through Google Home Now you can control your smart devices through Google Home Take bedroom light as the example the supported voice commands are as below Ok Google turn on off bedroom light Ok Google set bedroom light to 50 percent Ok Google brighten bedroom light Ok Google dim bedroom light Ok Google set bedroom light to red ...

Page 7: ...a consumer MP Global s sole responsibility shall be to repair or replace the product within the terms stated above MP GLOBAL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitat...

Reviews: