![MP Filtri ICM User Manual Download Page 11](http://html.mh-extra.com/html/mp-filtri/icm/icm_user-manual_1842937011.webp)
Specification
11
3.2 Hydraulic
Fluid Compatibility
Standard unit: Mineral oil & petroleum based fluids . See section 2 or con-
sult MP Filtri UK for other fluids.
Flow Rate
20-400 ml/minute
Viscosity Range
<1000 cSt
Fluid Temperature
-25 to +85 °C (check for viscosity compatibility for low temperature)
Maximum Pressure
420 bar static. For high frequency pressure pulse applications contact MP
Filtri UK.
Differential (Inlet-Outlet)
Pressure
Typically 0.5 bar, see section 15.1.
Seal Material [M,N]
Viton. Contact MP Filtri UK for any fluids that are incompatible with Viton
seals.
Seal Material [S]
Perflouro-elastomer.
3.3 Environmental
Ambient Temperature
-25 to + 80 °C for non Kversion, -25 to + 55°C for Kversion
IP Rating
IP66
3.4 Physical
Dimensions
123mm(H)x142mm(W)x65mm(D).
Fixing Holes
Centers 126mm apart, Diameter 6.9mm (for M6).
Weight
1.4kg