Serial Port Powered Media Conversion Solution
Transio
TCC-80/80-DB9 User’s Manual
P/N: 1802000800011
Third Edition.
www.moxa.com
©2008
Moxa
Inc.
Moxa Inc.
All rights reserved.
RS-422/RS-485 Pinouts
The RS-422/RS-485 port with terminal block
connector is shown below. Note that some
RS-422/485 devices “B” instead of “+” and use “A”
instead of “-”. That is, Data (B) equals Data (+), and
Data (A) equals Data (-).
+
T
T
+
D
/
+
R
R D
/
D
N
G
5
4
3
2
1
9
8
7
6
PIN RS-422/485
1 T+
2 T-
3 R+/D+
4 R-/D-
5 GND
USB Power Cord
The TCC-80 can be connected to a standard 5 to 12
VDC power supply, or you may use the
USB
Power Cord CBL-USBAP-50
if additional
external power is required.
USB “A” Male Connector
:
t
n
o
r
F
1
2
3
4
:
p
o
T
TCC-80
USB Connector
Connector Pinouts
Signals
1 +5
VDC
2 --
3 --
4 GND
0
8
-
C
C
T
r
e
n
n
i
r
e
t
u
o
g
u
l
P
r
e
w
o
P
C
D
0
5
-
P
A
B
S
U
-
L
B
C
B
S
U
t
s
o
H
B
S
U
e
l
a
m
e
F
e
p
y
T
A
C
D
V
5
+
D
N
G
g
n
i
r
i
W
e
l
b
a
C
1
4
C
D
V
2
1
)
.
x
a
m
(
A
m
0
1
2.1–0.1
5.1–0.1
Transio
TCC-80 V2.2 /
TCC-80-DB9 V1.0
Self-powered RS-232 to RS-422, 2-wire/4-wire
RS-485 bi-directional converter with 15 KV ESD
protection
Overview
The TCC-80, which is powered by the RS-232 port,
provides complete signal conversion between
RS-232 and RS-422/485 devices. The TCC-80
converts back and forth between RS-232’s TxD and
RxD lines, and either half duplex RS-485 or the
balanced signal of full duplex 4-wire RS-422/485.
In addition, the TCC-80 provides comprehensive 15
KV ESD protection for all serial lines. The TCC-80
is also designed to provide RS-485 auto data
direction control, in which the RS-485 driver is
enabled automatically when the circuitry senses the
TxD output from the RS-232 signal. Programming
is not required to control the transmission direction
of the half duplex RS-485 signal.
Package Checklist
•
TCC-80 or TCC-80-DB9
•
USB Power Cord
•
User’s Manual
Applications
•
Multipoint data acquisition
•
Factory automation
•
Remote serial device control
•
Building security automation
•
Critical industrial control
Features and Specifications
•
Serial interfaces: RS-232, RS-422, and
2-wire/4-wire RS-485.
•
Port types: Female DB9 for RS-232; Terminal
Block for RS-422/485
•
Compact size.
•
Auto senses baudrates up to 115.2 Kbps.
•
Signals:
RS-232: TxD, RxD, GND
RS-422: TxD+ (B)/-(A), RxD+ (B)/-(A), GND
RS-485: Data+ (B)/-(A), GND
•
RS-232 loopback:
RTS to CTS, and DTR to DSR and DCD.
•
Supports automatic RS-485 data direction control
with no baudrate switch settings for RS-485.
•
15 KV ESD protection for all RS-232/422/485
signals.
•
Built-in 120 ohm termination resistors for
RS-422/RS-485 (DIP switch selectable).
•
Supports up to 32 units connected in an RS-485
multi-drop network.
•
Serial Power Source: TxD, RTS, or DTR.
•
External Power (jack): DC +5V to +12V adaptors
or a USB power cord (DC +5V).
•
Operating temperature: 0 to 60°C (32 to 140°F).
•
Dimensions: 42
×
80
×
22 mm.
•
Case: ABS + PC.
•
Weight: 50
±
5 g.
•
CE, FCC Class B approval.
•
Power Consumption: 10 mA at +5 VDC
(termination disabled).
•
Warranty: 5 years.