![Moxa Technologies ToughNet User Manual Download Page 17](http://html1.mh-extra.com/html/moxa-technologies/toughnet/toughnet_user-manual_1842450017.webp)
ToughNet NAT Router User's Manual
TN-5916 Series Features and Functions
3-6
NOTE
Changing the time zone will automatically correct the current time. Be sure to set the time zone before setting
the time.
Time Server IP/Name
Setting
Description
Factory Default
IP address or name of
time server
The IP or domain address (e.g., 192.168.1.1,
time.stdtime.gov.tw, or time.nist.gov).
None
IP address or name of
secondary time server
The Moxa switch will try to locate the secondary NTP server if
the first NTP server fails to connect.
Enable NTP/SNTP Server
Setting
Description
Factory Default
Enable/Disable
Enables SNTP/NTP server functionality for clients
Disabled
Warning Notification
Since industrial Ethernet devices are often located at the endpoints of a system, these devices will not always
know what is happening elsewhere on the network. This means that an ToughNet NAT Router that connects to
these devices must provide system maintainers with real-time alarm messages. Even when control engineers
are out of the control room for an extended period of time, they can still be informed of the status of devices
almost instantaneously when exceptions occur. The Moxa ToughNet NAT Router supports different approaches
to warn engineers automatically, such as email, trap, syslog and relay output. It also supports one digital input
to integrate sensors into your system to automate alarms by email and relay output.
System Event Settings
System Events are related to the overall function of the switch. Each event can be activated independently with
different warning approaches. Administrator also can decide the severity of each system event.
System Events
Description
Cold Start
Power is cut off and then reconnected.
Warm Start
Moxa ToughNet NAT Router is rebooted, such as when network parameters
are changed (IP address, subnet mask, etc.).
Power Transition (On
Off)
Moxa ToughNet NAT Router is powered down.
Power Transition (Off
On)
Moxa ToughNet NAT Router is powered up.
Configuration Change
Any configuration item has been changed
Authentication Failure
An incorrect password was entered.