Moxa Technologies RKS-4028-L3 Series Quick Installation Manual Download Page 1

 

 

P/N:1802040000041 

*1802040000041* 

RKS-G4028/ 

RKS-4028-L3  Series   

Quick Installation Guide 

 

Version 1.1, August 2022 

Technical Support Contact Information 

www.moxa.com/support 

 

 

 

 

 

 

 

 

 

 

 

 2022 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for RKS-4028-L3 Series

Page 1: ...P N 1802040000041 1802040000041 RKS G4028 RKS 4028 L3 Series Quick Installation Guide Version 1 1 August 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights reserved ...

Page 2: ...Warranty card Panel Layouts Front View RKS G4028 4GS Series RKS G4028 4GT Series Rear View 1 System status LEDs 2 microSD card socket cover 3 Reset button 4 USB host type A 5 Console port RS 232 RJ45 6 Module 1 7 Module 2 socket 8 Module 3 socket 9 Module 4 socket 10 Relay output 11 EPS external power supply inputs 12 Power input 1 for 110 220 VDC VAC 13 Power input 2 for 110 220 VDC VAC 14 Model ...

Page 3: ... 3 Dimensions RM G4000 Ethernet Interface Modules 4MSC2TX 4MST2TX 4SSC2TX 2MSC4TX 2MST4TX 2SSC4TX 6MSC 6MST ...

Page 4: ...f procedures other than those specified herein may result in hazardous radiation exposure Grounding the Moxa Industrial Rackmount Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices NOTE Using a shielded cable achieves better electromagnetic com...

Page 5: ...on with a Safety Extra Low Voltage SELV or an isolated power supply which means that they may only be connected to the supply voltage connections and to the signal contact with a SELV or an isolated power supply in compliance with IEC 62368 1 EN 62368 1 UL 62368 1 or UL 61010 Power Terminal Blocks The connection for EPS external power supply PWR1 power supply 1 and PWR2 power supply 2 are located ...

Page 6: ...cable terminals The rated temperature of wiring should be at least 105 C NOTE When wiring the grounding connector screw we suggest using the cable type AWG American Wire Gauge 16 1 31 mm2 and the corresponding pin type cable terminals The rated temperature of wiring should be at least 105 C NOTE When HV models are connected with an AC power source please make sure the Ground wire is well connected...

Page 7: ...f 115200 Refer to the following table figure for the pin definition Pin Description 1 2 3 4 TxD 5 RxD 6 GND 7 8 The Reset Button Depress the Reset button for five continuous seconds to load the factory default settings Use a pointed object such as a straightened paper clip or toothpick to depress the Reset button When you do so the STATE LED will start to blink about once per second Continue to de...

Page 8: ...being supplied to the main module s power input PWR1 Off Power is not being supplied to the main module s power input PWR1 P2 PWR2 Amber On Power is being supplied to the main module s power input PWR2 Off Power is not being supplied to the main module s power input PWR2 S STATE Green On The system passed the self diagnosis test on boot up and is ready to run Blinking 1Hz 1 System service initiali...

Page 9: ...oming function is enabled 2 The switch is set as the Tail of the Turbo Chain Blinking 1 The switch is set as the Tail of Turbo Chain and the Chain has gone down 2 The switch is set as Turbo Chain s Member Head and the corresponding Tail end Chain port has gone down Off When the switch disables the coupling or the Tail of Turbo Chain SYNC Amber On The PTP function is enabled Blinking The switch rec...

Page 10: ...iption Copper 10 100 1000 Mbps Green On The corresponding port s 1000 Mbps link is active Blinking Data is being transmitted at 1000 Mbps Off The corresponding port s link is inactive Amber On The corresponding port s 10 100 Mbps link is active Blinking Data is being transmitted at 10 100 Mbps Off The corresponding port s link is inactive SFP 100 1000 Mbps Green On The corresponding port s 1000 Mb...

Page 11: ...corresponding port s link is inactive RM G4000 8GPoE LED Color State Description Copper 10 100 1000 Mbps Green On The corresponding port s 1000 Mbps link is active Blinking Data is being transmitted at 1000 Mbps Off The corresponding port s link is inactive Amber On The corresponding port s 10 100 Mbps link is active Blinking Data is being transmitted at 10 100 Mbps Off The corresponding port s li...

Page 12: ... at powered device PD Blinking PoE power has been shut off because power budget is low Off 1 Power is not being supplied to a powered device PD 2 The port is not connected to an IEEE 802 3bt at af standard powered device PD Specifications Input Output Interface Alarm Contact Channels 1 relay output with current carrying capacity of 2 A 24 VDC Ethernet Interface 10 100 1000BaseT X Ports RJ45 connec...

Page 13: ...ation Power Parameters Input Voltage RKS G4028 LV Models 24 48 VDC RKS G4028 2LV Models 24 48 VDC redundant dual inputs RKS G4028 HV Models 110 220 VAC 110 220 VDC RKS G4028 2HV Models 110 220 VAC 110 220 VDC redundant dual inputs PoE Models 48 VDC for PoE system Operating Voltage RKS G4028 LV Models 18 to 72 VDC RKS G4028 2LV Models 18 to 72 VDC RKS G4028 HV Models 85 to 264 VAC 88 to 300 VDC RKS...

Page 14: ...tal Limits Operating Temperature 40 to 75 C 40 to 167 F Storage Temperature package included 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Standards and Certifications Safety EN 62368 1 UL 62368 1 UL 61010 EMC EN 55032 35 EMI CISPR 32 FCC Part 15B Class A EMS IEC 61000 4 2 ESD Contact 8 kV Air 15 kV IEC 61000 4 3 RS 80 MHz to 1 GHz 35 V m IEC 61000 4 4 EFT Power 4 kV Sign...

Page 15: ...be such that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading 4 Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the ci...

Page 16: ... with a key or through a security identity system External metal parts of this equipment are extremely hot Before touching the equipment you must take special precautions to protect your hands and body from serious injury Patent https www moxa com doc operations Moxa_Patent_Marking pdf ATTENTION 1 To protect against the risk of fire only replace the fuse with one that has the same type and rating ...

Reviews: