Moxa Technologies OnCell 3120-LTE-1 Quick Installation Manual Download Page 1

 

 

P/N: 1802031200010 

*1802031200010* 

OnCell 3120-LTE-1 

Quick Installation Guide 

Moxa OnCell Series 

Version 1.0, October 2019 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2019 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for OnCell 3120-LTE-1

Page 1: ...port Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 0...

Page 2: ...y The OnCell 3120 LTE 1 also comes with a 3 in 1 serial port for serial over LTE cellular network communication making it suitable for collecting and exchanging data with serial Ethernet devices Packa...

Page 3: ...3120 LTE 1 to a computer See the 10 100BaseT X Ethernet Port Connection section below for detailed instructions If the LAN LED indicator on the OnCell 3120 LTE 1 lights up it means a connection has b...

Page 4: ...ular antenna port 3 10 100 Base T X Ethernet port 1 RJ45 4 10 100 Base T X Ethernet port 2 RJ45 5 USB port 6 DB9 serial port 7 LED display 8 Reset button 9 Console port reserved for engineering use 10...

Page 5: ...he back panel Mount the OnCell 3120 LTE 1 Series on corrosion free mounting rails that meet the EN 60715 standard Installation STEP 1 Insert the upper lip of the DIN rail into the top hook of the DIN...

Page 6: ...OnCell 3120 LTE 1 device with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should b...

Page 7: ...y First Be sure to disconnect the power cord before installing and or wiring the OnCell 3120 LTE 1 device Read and Follow These Guidelines Use separate paths to route wiring for power and devices If p...

Page 8: ...e zero If the potential difference is NOT zero the product could be permanently damaged SIM Card Socket The OnCell 3120 LTE 1 comes with two nano SIM card sockets for cellular communication The nano S...

Page 9: ...e OnCell 3120 LTE 1 ATTENTION Before connecting the OnCell 3120 LTE 1 to the DC power inputs make sure that the DC power source voltage is stable Communication Connections 10 100Base T X Ethernet Port...

Page 10: ...3120 LTE 1 The function of each LED is described in the table below LED Color Behavior Function SYS 2 LEDs Green Power On System startup is complete and the system is in operation Off No power is sup...

Page 11: ...r signal strength Specifications Input Current 0 8 A max Input Voltage 9 to 36 VDC Power Consumption 5 W typ Operating Temperature Standard Models 0 to 55 C 32 to 131 F Wide Temp Models 30 to 70 C 22...

Page 12: ...NFPA 70 National Electrical Code Article 810 and Canada Canadian Electrical Code Section 54 ATTENTION For EXPLOSION PROOF applications the OnCell 3120 LTE 1 is designed and certified to meet ATEX and...

Page 13: ...2 I SH 01 2013 11 I SH 02 2014 10 IEC 60079 15 4th Edition 2010 01 I SH 01 2016 09 5 Conditions for Safe Usage These devices shall be mounted in a suitable tool accessible ATEX IECEx certified enclosu...