background image

 

— 1 — 

— 2 — 

— 3 — 

 

NPort DE-311 

Quick Installation Guide 

 

Second Edition, October 2004 

1. Overview 

Welcome to Moxa NPort Express DE-311, a compact palm-sized data 
communication device that allows you to control RS-232/422/485 
serial devices over a TCP/IP based Ethernet. 

2. Package Checklist

 

Before installing DE-311, verify that the package contains the 
following items: 

!

 

1 NPort DE-311 Universal Serial Device Server 

!

 

NPort Express Quick Installation Guide for DE-311 

!

 

Power Adaptor 

!

 

NPort Documentation & Software CD 

!

 

Mini Adaptor 

Optional Accessories

 

!

 

DK-35A (for 35 mm DIN-Rail; includes 4 screws) 

Notify your sales representative if any of the above items is missing or 
damaged. 

3. Hardware Introduction 

 

Female DB9 serial port

DIP Switches

Front Panel View

ON

1 2 3

 

 

Top Panel View

DE-311 RS-232/422/485 Device Server

Express

PWR

Link

Ready

Serial

DC-IN

SW

RESET 10/100M

Ethernet

DIN-Rail
screw hole

Wallmount
screw hole

 

RJ45 10BaseT Ethernet port

Reset button

Power input 

Rear Panel View

 

Reset Button

—Press the 

Reset button

 continuously for 

a.

 

3 sec to erase the password 
A

fter 3 sec, the ready LED will flash on/off every half second. 

Release the reset button at this time to erase the password.

 

b.

 

10 sec to load factory defaults

 

After 10 sec, the ready LED will flash on/off every fifth of a second. 
Release the reset button at this time to load factory defaults.

 

LED Indicators

—DE-311’s top panel contains three LED indicators, as 

described in the following table. 

LED Name  LED Color 

LED Function 

red 

Power is on. 

PWR 

off 

Power is off, or power error 
condition exists. 

orange 

10 Mbps Ethernet connection. 

green 

100 Mbps Ethernet connection. 

Link 

off 

Ethernet cable is disconnected, or 
has a short. 

green 

System is ready. 

Ready 

off 

System error. 

 
4. Hardware Installation Procedure 

Placement Options 

 

 

In addition to placing 
the DE-311 unit on a 
desktop or other 
horizontal surface, you 
may also make use of 
the DIN-Rail or Wall 
Mount options, as 
illustrated here. 

Wall Mount 

DE-311 RS-232/422/485 Device Server

Express

PWR

Link

Ready

Serial

DC-IN

SW

RESET 10/100M

Ethernet

 

DIN-Rail 

 

DIP Switch Settings and Explanation 

The top panel of DE-311 contains the following table, which describes 
how to set up the serial port using the three DIP switches located on 
DE-311’s rear panel.

 

SW1 

Serial 

Connection 

SW2 SW3 

Interface 

Mode 

ON 

RS-232 

Console 

— — 

— — — 

OFF OFF 

RS-232 

OFF ON 

RS-422 

ON 

OFF 

2-wire RS-485 by RTS 

OFF 

Data 

Comm

 

ON 

ON 

2-wire RS-485 by ADDC 

Switch SW1 controls the function of the serial port. Note that after 
changing the setting of SW1, DE-311 will reboot to initialize the new 
setting. You must wait a few seconds for the green Ready light to blink 
off and then on again, indicating that the function of the serial port has 
been changed. Switches SW2 and SW3 control the serial port’s data 
communication Interface Mode. (Note that RTS stands for Ready To 
Send and ADDC stands for Automatic Data Direction Control.) 

Keep the following points in mind when setting the DIP switches: 

!

 

To use the serial port as an RS-232 console connection, such as when 
using MOXA PComm Terminal Emulator or HyperTerminal, set SW1 
to the ON position. 

!

 

Some setup procedures can be carried out through a Telnet connection, 
during which data is transmitted through DE-311’s Ethernet port. You 
must set SW1 to the OFF position to establish a Telnet connection. 

 
5. Software Installation Information 

Detailed information about installing the software that comes with 
DE-311can be found on the NPort Documentation & Software CD in the 
“NPort Family Software Installation Guide.” 

 

P/N: 18020031141

Reviews: