LED Indicators
—The top panels of NPort 5200 have four LED
indicators, as described in the following table.
5200 Series
Quick Installation Guide
Second Edition, December 2003
LED
Name
LED
Color
LED Function
red
Steady on: Power is on and NPort 5200 is
booting up.
Blinking:
Indicates an IP conflict, or DHCP or
BOOTP server did not respond
properly.
green
Steady on: Power is on and NPort 5200 is
functioning normally.
Blinking:
The device server has been located
by Administrator’s Location
function
Ready
off
Power is off, or power error condition exists.
orange 10 Mbps Ethernet connection.
green 100 Mbps Ethernet connection.
Ethernet
off
Ethernet cable is disconnected, or has a short.
orange Serial port is receiving data.
green Serial port is transmitting data.
P1, P2
off
No data is being transmitted or received through
the serial port.
1. Overview
Welcome to the NPort 5200 Series, a compact palm-sized data
communication device that allows you to control RS-232 (NPort
5210/5230) or RS-422/485 (NPort 5230/5232/5232I) serial devices over a
TCP/IP-based Ethernet.
2. Package Checklist
Before installing the NPort 5200 Series products, verify that the package
contains the following items:
1 NPort 5200 2-port Serial Device Server
Documentation & Software CD
NPort 5200 Series Quick Installation Guide
Optional Accessories
DK-35A
DIN-Rail Mounting Kit (35 mm)
CBL-RJ45M9-150
CBL-RJ45F9-150
CBL-RJ45M25-150
CBL-RJ45F25-150
RJ45 (8-pin) to DB9 (M) cable, 150 cm
RJ45 (8-pin) to DB9 (F) cable, 150 cm
RJ45 (8-pin) to DB25 (M) cable, 150 cm
RJ45 (8-pin) to DB25 (F) cable, 150 cm
DIN-Rail Power Supply and Adapter
4. Hardware Installation Procedure
STEP 1
: After removing NPort 5200 from the box, the first thing you
should do is connect the power adaptor. Connect the 12-30 VDC power
line with NPort 5200’s terminal block, or connect the DIN-Rail power
supply with NPort 5200’s terminal block.
STEP 2
: Connect NPort 5200 to a network. Use a standard
straight-through Ethernet cable to connect to a Hub or Switch. When
setting up or testing NPort 5200, you might find it convenient to connect
directly to your computer’s Ethernet port. In this case, use a cross-over
Ethernet cable.
Notify your sales representative if any of the above items is missing or
damaged.
3. Hardware Introduction
As shown in the following figures, NPort 5210 has two 8-pin RJ45 ports,
both for the RS-232 interface, NPort 5230 has one 10-terminal terminal
block, with 5 pins used for one RS-232 port, and 5 pins used for one
RS-422/485 port, and NPort 5232 /5232I has one 10-terminal terminal
block, with all pins used for RS-422/485 ports.
STEP 3
: Connect NPort 5200’s serial port to a serial device.
Reset Button
—Press the
Reset button
continuously for
5 sec to load
factory defaults
: Use a pointed object, such as a straightened paper clip or
toothpick, to press the reset button. This will cause the Ready LED to
blink on and off. The factory defaults will be loaded once the Ready LED
stops blinking (after about 5 seconds). At this point, you should release
the reset button.
—