Overview 

The MGate MB3660 (MB3660-8 and MB3660-16) series gateways 
are 8 and 16-port redundant Modbus gateways that convert 
between the Modbus TCP and Modbus RTU/ASCII protocols. The 
gateways come with built-in dual AC or DC power inputs for power 
redundancy, and have dual Ethernet ports (with different IPs) for 
network redundancy. 
The MGate MB3660 series gateways provide not only 
serial-to-Ethernet communication, but also 
serial(Master)-to-serial(Slave) communication, and can be 
accessed by up to 256 TCP master/client devices, or connected to 
128 TCP slave/server devices. 
Each serial port can be configured individually for Modbus RTU or 
Modbus ASCII operation and for different baudrates, allowing both 
types of networks to be integrated with Modbus TCP through one 
Modbus gateway. 

Package Checklist 

Before installing the MGate MB3660 series gateway, verify that the 
package contains the following items: 

 

1 MGate MB3660-8 or MB3660-16 gateway 

 

1 RJ45-to-DB9 female serial cable for console setting 

 

2 L-shaped brackets for wall mounting 

 

2 AC power cords (for AC models) 

 

Documentation and software CD 

 

Quick installation guide 

 

Product warranty statement 

Optional Accessories 

 

Mini DB9F-to-TB Adapter:

 DB9 female to terminal block 

adapter for RS-422/485 applications 

 

CBL-RJ45M9-150:

 8-pin RJ45 to DB9 male cable, 150 cm 

 

CBL-RJ45F9-150:

 8-pin RJ45 to DB9 female cable, 150 cm 

Notify your sales representative if any of the above items are 
missing or damaged. 

 
 
 
 
 

Hardware Introduction 

As shown in the following figures, the MGate MB3660-8 has 8 
DB9/RJ45 ports for transmitting serial data, and the MGate 
MB3660-16 has 16 DB9/RJ45 ports for transmitting serial data. 
The MGate MB3660I series gateways provide 2 kV serial port 
isolation protection. 

 

AC-DB9 Models 

    

 

DC-DB9 Models 

    

 

AC-RJ45 Models 

    

 

    

 

Reset Button— 

Press the Reset button continuously for 5 sec to 

load factory defaults

 

The reset button is used to load factory defaults. Hold the reset 
button down for five seconds using a pointed object such as a 

straightened paper clip. Release the reset button when the Ready 
LED stops blinking. 

LED Indicators 

Name 

Color 

Function 

PWR 1, 
PWR 2 

Red  Power is being supplied to the power input 

Off  Power cable is not connected 

Ready 

Red 

Steady on: Power is on and the unit is booting 
up 
Blinking: IP conflict, DHCP, or BOOTP server 
did not respond properly, or a relay output 
occurred 

Green 

Steady on: Power is on and unit is functioning 
normally 
Blinking: Unit is responding to the locate 
function 

Off  Power is off, or power error condition exists 

Tx   

Green  Serial port is transmitting data 

Rx   

Amber  Serial port is receiving data 

LAN 1, 
LAN 2 

Green  Indicates 100 Mbps Ethernet connection 

Amber  Indicates 10 Mbps Ethernet connection 

Off  Ethernet cable is disconnected 

Hardware Installation Procedure 

STEP 1: 

After unpacking the unit, connect the power supply to the 
unit. 

STEP 2: 

Use an Ethernet cable to connect the unit to the network. 

STEP 3: 

Connect your device to the desired port on the unit. 

STEP 4: 

Place or mount the unit. The unit may be placed on a 
horizontal surface such as a desktop, or mounted on the 
wall. 

 

Wall or Cabinet Mounting 

Two metal plates are provided for mounting the 
unit on a wall or inside a cabinet. Attach the 
plates to the unit’s rear panel with screws. With 
the plates attached, use screws to mount the unit 
on a wall. 
For each screw, the head should be 6.0 mm or 
less in diameter, and the shaft should be 3.5 mm 
or less in diameter. 

 

 

Termination Resistor and Adjustable Pull High/Low 
Resistors 

In some critical environments, you may need to add termination 
resistors to prevent the reflection of serial signals. When using 
termination resistors, it is important to set the pull high/low 
resistors correctly so that the electrical signal is not corrupted. The 
MGate MB3660 uses DIP switches to set the pull high/low resistor 
values for each serial port. To expose the DIP switches located on 