Moxa Technologies IMC-101G Series Quick Installation Manual Download Page 1

 

 

P/N: 1802001014017 

*1802001014017* 

IMC-101G Series 

Quick Installation Guide 

Moxa Industrial Media Converter 

Edition 7.0, February 2017 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2017 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for IMC-101G Series

Page 1: ...om support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89...

Page 2: ...ensuring that your Ethernet equipment can withstand a variety of application environments such as hazardous locations Class 1 Division 2 Zone 2 IECEx and complies with CE FCC and UL Standards Package...

Page 3: ...issipation vents 4 Dip switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 SFP port s 1000 Mpbs G2 LED 9 TP port s 1000 Mpbs G1 LED 10 1000BaseSFP fiber port 11 10 100 1000BaseT X por...

Page 4: ...to reattach the DIN rail attachment plate to the IMC 101G make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN rail into the slo...

Page 5: ...be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure on the right NOTE Test the screw head and shank size by inserting the screw into one of the...

Page 6: ...hall be made either in the equipment or external to the equipment to provide the transient protection device to be set at a level not exceeding 140 of the peak rated voltage 6 Additional use guide The...

Page 7: ...r electrical characteristics can be bundled together Keep input wiring and output wiring separate It is strongly advised that you label wiring to all devices in the system when necessary Grounding the...

Page 8: ...ch is set to ON is not properly connected If neither of these two conditions is met the fault circuit will be closed Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts...

Page 9: ...connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB switch type ports and also show cable wiring diagrams for straight through and crossover Ethernet c...

Page 10: ...ther optical line is used to transmit data from device II to device I for full duplex transmission Remember to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx r...

Page 11: ...PORT ALARM DIP Switch is set to ON is not properly connected If neither of these two conditions occurs the fault circuit will be closed IMC 101G DIP Switch Setting NOTE To activate updated DIP switch...

Page 12: ...TP port s 100 Mbps link is inactive Auto MDI MDI X Connection The Auto MDI MDI X function allows users to connect the IMC 101G s 10 100 1000BaseT X ports to any kind of Ethernet device without paying...

Page 13: ...rt DIP Switches Port break alarm mask Link Fault Pass through SFP AN Force Alarm Contact One relay output with current carrying capacity of 1 A 24 VDC resistive Optical Fiber 1000BaseSX LSX LX LH LHX...

Page 14: ...Protection Supported Mechanical Casing Metal IP30 protection Dimensions W x H x D 53 x 135 x 105 mm 2 1 x 5 3 x 4 1 in Weight 630 g Installation DIN rail or wall mounting optional kit Environmental L...