Moxa Technologies IKS-G6524A Quick Installation Manual Download Page 1

 

 

P/N: 1802065240025 

*1802065240025* 

IKS-G6524A/G6824A Series 

Quick Installation Guide 

 

Version 3.3, March 2020 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2020 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for IKS-G6524A

Page 1: ...xa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0...

Page 2: ...d 4 protective caps for unused ports 2 rackmount ears Quick installation guide printed Warranty card Panel Layouts 1 Model Name 2 System status LEDs 3 10 100 1000BaseT X port status LEDs 4 100 1000Bas...

Page 3: ...pply 1 PWR1 and Power Supply 2 PWR2 The connections for PWR1 and PWR2 are located on the rear side shown below Be sure to use a standard power cord with an IEC C13 connector which is compatible with t...

Page 4: ...backup configurator to connect the IKS G6524A G6824A s USB storage port for configuration backup firmware upgrade or system log file backup USB Storage Port Type A Connector Pinouts Pin Description 1...

Page 5: ...r is being supplied to the main module s power input PWR2 Off Power is not being supplied to the main module s power input PWR2 FAULT RED On The system has failed or is under quick inspection Off The...

Page 6: ...E 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x for Flow Control IEEE 802 1D 2004 for Spanning Tree Protocol IEEE 802 1w for Rapid Spanning Tree Protocol IEEE 802 1s for Multiple Spanning Tree Protocol...

Page 7: ...olarity Protection Present Physical Characteristics Housing IP 30 protection Dimensions 440 x 44 x 386 9 mm 17 32 x 1 73 x 15 23 in Installation 19 rack mounting Environmental Limits Operating Temp St...

Page 8: ...nd the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this conce...

Page 9: ...rth ground to adequately ground the chassis and protect the operator from electrical hazards To avoid risks of electric shock do not replace or remove the protective conductor 5 The IP rating is not p...