Moxa Technologies IKS-G6524 Hardware Installation Manual Download Page 1

 

 

– 1 – 

– 2 – 

– 3 – 

P/N: 1802068240010 

IKS-G6524/G6824 Series 

Hardware Installation Guide 

First Edition, May 2011 

Package Checklist 

The Moxa IKS-G6524/G6824 Series industrial rackmount switches 
are shipped with the following items. If any of these items are 
missing or damaged, please contact your customer service 
representative for assistance. 

 

IKS-G6524/G6824 switch 

 

RJ45 to DB9 console port cable 

 

2 power cords 

 

Protective caps for unused ports 

 

2 rackmount ears 

 

Documentation and software CD 

 

Hardware installation guide (printed) 

 

Warranty card 

Panel Layouts 

 

1.

 

Model Name 

2.

 

System status LEDs 

3.

 

10/100/1000 BaseT(X) port status LEDs 

4.

 

100/1000Base SFP port status LEDs 

5.

 

10/100/1000 BaseT(X) port 

6.

 

100/1000Base SFP slot 

7.

 

10/100/1000 BaseT(X) or 100/1000Base SFP slot combo ports 

8.

 

Serial Console port 

9.

 

Terminal block for Relay Output, Digital Input 

10.

 

AC power sockets for power inputs 

11.

 

Grounding screw 

Dimensions (unit = mm) 

 

Grounding the Moxa Industrial Rackmount 

Switch 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection 
from the ground screw to the grounding surface prior to connecting 
devices. 

Connecting the Power Inputs 

The IKS-G6524/G6824 series of switches supports dual redundant 
power supplies: 

Power Supply 1 (PWR1) 

and 

Power Supply 2 

(PWR2)

. The connections for PWR1 and PWR2 are located on the 

rear side (shown below). Be sure to use a standard power cord 
with an IEC C13 connector, which is compatible with the AC power 
inlet. 

 

LED Indicators 

The front panel of the IKS-G6524/G6824 Series switch contains 
several LED indicators. The function of each LED is described in the 
table below. 

LED 

Color 

State 

Description 

System LEDs 

STAT 

GREEN 

On 

System has passed 
self-diagnosis test on 
boot-up and is ready to run. 

Blinking 

System is undergoing the 
self-diagnosis test. 

RED 

On 

System failed self-diagnosis 
on boot-up. 

PWR1 

AMBER 

On 

Power is being supplied to 
the main module’s power 
input PWR1. 

Off 

Power is not being supplied 
to the main module’s power 
input PWR1. 

PWR2 

AMBER 

On 

Power is being supplied to 
the main module’s power 
input PWR2. 

Off 

Power is not being supplied 
to the main module’s power 
input PWR2. 

FAULT 

RED 

On 

System is in the event of 
failure, or is under quick 
inspection. 

Off 

System is in normal 
operation. 

MSTR/ 
HEAD 

GREEN 

On 

When the IKS-G6524/G6824 
is set as the Master of the 
Turbo Ring, or as the Head of 
the Turbo Chain. 

Blinking 

The IKS-G6524/G6824 has 
become the Ring Master of 
the Turbo Ring, or the Head 
of the Turbo Chain, after the 
Turbo Ring or the Turbo 
Chain is down. 

Off 

The IKS-G6524/G6824 is not 
the Master of this Turbo Ring 
or is set as a Member of the 
Turbo Chain 

CPLR/ 
TAIL 

GREEN 

On 

When the IKS-G6524/G6824 
coupling function is enabled 
to form a back-up path, or 
when it’s set as the Tail of 
the Turbo Chain. 

Blinking 

When the Turbo Chain is 
down 

Off 

When this 
IKS-G6524/G6824 switch 
disables the coupling 
function. 

Reviews: