IEX-402-VDSL2 Series   

Quick Installation Guide 

Moxa Managed VDSL2 Ethernet Extender 

Version 2.2, January 2021 

Technical Support Contact Information 

www.moxa.com/support 

 

 

 

 

 

 

 

 

 

 

 

 2021 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for IEX-402-VDSL2 Series

Page 1: ...3 1802004020023 IEX 402 VDSL2 Series Quick Installation Guide Moxa Managed VDSL2 Ethernet Extender Version 2 2 January 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All...

Page 2: ...device will set one as CO and the other as CPE with auto CO CPE negotiation factory default setting Advanced management and monitoring functionalities through NMS including a virtual panel improve the...

Page 3: ...State LED 4 Fault LED 5 10 100BaseT X port 6 DSL speed SNR LED 7 Detachable 2 contact DSL port 8 Link ACT LED 9 TP port s 10 100 Mbps LED 10 DSL port RJ 45 RJ 11 connector 11 CO CPE LED 12 Model name...

Page 4: ...If you need to reattach the DIN rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the following figures STEP 1 Insert the top of the DIN rail into the slot...

Page 5: ...o one of the keyhole shaped apertures of the wall mounting plates Do not tighten the screws completely leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws S...

Page 6: ...E Do not run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately Use the type o...

Page 7: ...ing the IEX 402 VDSL2 to the DC power inputs make sure the DC power source voltage is stable Auto MDI MDI X Connection The Auto MDI MDI X function allows users to connect the IEX 402 VDSL2 s 10 100Bas...

Page 8: ...s of the terminal block connectors are shown here Step 1 Insert the wires into the Ring Tip terminals Step 2 To keep the wires from pulling loose use a small flat blade screwdriver to tighten the wire...

Page 9: ...to load the factory default settings Use a pointed object such as a straightened paper clip or toothpick to depress the Reset button This will cause the STATE LED to blink once a second After depress...

Page 10: ...se protection mode for the DSL connection STD mode Direct data transmission with less than 2 ms latency INP mode Data transmission with impulse noise protection Latency is under 8 ms with 500 s interl...

Page 11: ...in the event of failure or is under quick inspection Off System is in normal operation 10 100M TP port GREEN On The corresponding port s link is active Blinking The corresponding port s data is being...

Page 12: ...RJ 11 RJ 45 connector or detachable 2 contact terminal block Console RS 232 RJ45 LED Indicators PWR1 PWR2 FAULT 10 100M TP port STATE CO CPE LINK ACT DSL SPEED SNR DIP Switches Reset button CO CPE SNR...

Page 13: ...bpart B Class A CISPR EN55022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 EN61000 4 8 Shock IEC60068 2 27 Freefa...