Overview
Moxa’s FLI-1200 is an industrial auto-configuration server
appliance designed to automatically configure and monitor various
Moxa products in harsh industrial environments.
The FLI-1200 has a fanless, thermally efficient, dust- and
water-protected IP54-rated chassis. The sealed enclosure protects
the internal components from dust and splashed water, and is
compliant with the EN 50155 standard, covering operating
temperature, power input voltage, power surges, ESD, and
vibration, ensuring that the FLI-1200 can operate reliably under
extreme environments for rolling stock applications.
The FLI-1200 comes with Moxa’s FLI technology, which ensures
that the replacement or deployment of any Moxa device will not
affect the existing architecture, and eliminates the need to
perform manual reentry or reconfiguration. With its web-based
interface, users can easily manage the system and monitor the
status of any device being controlled by the FLI-1200, and its
reliable and robust design ensures that when the primary FLI
server is offline, the backup server will take over to keep the
auto-configuration functionality up and running. With the FLI-1200,
users can maintain Moxa’s products more efficiently, and realize a
considerable reduction in maintenance costs and human error.
Package Checklist
Before installing the FLI-1200, verify that the package contains the
following items:
•
FLI-1200 auto-configuration server appliance
•
Wall mounting kit
•
Quick installation guide (printed)
•
Warranty card
NOTE: Please notify your sales representative if any of the above
items are missing or damaged.
FLI-1200 Panel Layout
Front View
Rear View
LED Indicators
The following table describes the LED indicators located on the
front panel of the FLI-1200.
LED Name LED Color/
Status
LED Function
Ready
Green
System is ready
Blinking
once per
second
Reset to default
Off
System is not ready
LAN (1, 2)
Green,
blinking
100 Mbps Ethernet mode
Off
No Ethernet activity or operating at 10
Mbps
Act.
Red
This FLI-1200 is acting as the master
FLI server
Off
This FLI-1200 is not acting as master
FLI server
Installing the FLI-1200
The FLI-1200 comes with
two brackets for mounting it
on walls. Use two screws on
each side to attach the
FLI-1200 to a wall or
cabinet.
The FLI-1200 also comes
with an optional rack
installation kit. Simply slide
the FLI-1200 into the rack
mounting bracket to
complete the installation.
Refer to the FLI-1200
Hardware Manual for
more detailed installation
instructions.
Connector Description
Ethernet Ports
Two 10/100 Mbps Ethernet ports using M12 D-coded connectors
are located on the front panel. The pin assignments are shown in
the following figure and table.
Configuring Power Inputs
One 24 VDC power input using a 5-pin M12 connector is located on
the front panel. The pin assignments are shown in the following
figure and table.