Moxa Technologies EDS-405 User Manual Download Page 1

 

Moxa EtherDevice™ Switch 

EDS-405 User’s Manual 

Fifth Edition, June 2008 

 

 

©

 2008 Moxa Inc., all rights reserved. 

Reproduction without permission is prohibited. 

 

Summary of Contents for EDS-405

Page 1: ...Moxa EtherDevice Switch EDS 405 User s Manual Fifth Edition June 2008 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited...

Page 2: ...tment on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make...

Page 3: ...s Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89...

Page 4: ...ional 2 4 Chapter 3 Wiring EDS 405 3 1 Wiring Requirements 3 2 Grounding EDS 405 3 4 Wiring the Alarm Contact 3 4 Wiring the Redundant Power Inputs 3 5 Communication Connections 3 6 10 100BaseT X Ethe...

Page 5: ...MDI X Connection 4 11 Fiber Ports 4 11 Dual Speed Functionality and Switching 4 12 Switching Filtering and Forwarding 4 12 Switching and Address Learning 4 13 Auto Negotiation and Speed Sensing 4 13...

Page 6: ...by Moxa for industrial Ethernet switches With this plug n play ring redundancy solution your industrial automation and control applications can operate non stop The following topics are covered in thi...

Page 7: ...promptly to emergency situations Commercial Ethernet switches need 3 to 5 minutes to recover the connection when you unplug your device from one port and then plug it into another port for field diag...

Page 8: ...ative if any of the above items is missing or damaged Product Features EDS 405 has the following features y Plug n play ring redundancy solution recovery time 300 ms y Relay output alarm for power fai...

Page 9: ...lt LED 8 Ring Master LED 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 10 100BaseT X Port 13 Screw hole for optional wall mounting kit 14 DIN Rail kit EDS 405 1 2 3 4 5 10M 100M P...

Page 10: ...100M 100M RING MASTER 12 13 NOTE The appearance of EDS 405 SS SC is identical to EDS 405 MM SC 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices...

Page 11: ...05 MM ST 1 2 3 4 5 PWR1 PWR2 FAULT 10M 100M 100M 100M RING MASTER 12 13 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Dip switches 5 Power...

Page 12: ...2 2 Chapter 2Installing EDS 405 This chapter includes information about how to install EDS 405 The following topics are covered Mounting Dimensions DIN Rail Mounting Wall Mounting Optional...

Page 13: ...View Front View 9 75 13 90 5 10 10 26 6 Panel Mount Kit unit mm 13 10 21 00 15 10 105 00 25 40 13 90 18 20 25 71 23 15 7 75 30 50 7 75 3 50 6 00 3 50 6 00 39 37 46 77 135 00 30 00 9 50 54 00 13 18 13...

Page 14: ...Rail attachment plate to EDS 405 make sure the stiff metal spring is situated towards the top as shown in the figures below 1 Insert the top of the DIN Rail into the slot just below the stiff metal sp...

Page 15: ...h wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diamet...

Page 16: ...crew heads through the large parts of the keyhole shaped apertures and then slide Moxa EDS 405 downwards as indicated below Tighten the four screws for stability EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 F...

Page 17: ...mation about wiring EDS 405 The following topics are covered Wiring Requirements Grounding EDS 405 Wiring the Alarm Contact Wiring the Redundant Power Inputs Communication Connections 10 100BaseT X Et...

Page 18: ...nly be connected to the supply voltage connections and to the signal contact with the Safety Extra Low Voltages SELV in compliance with IEC950 EN60950 VDE0805 WARNING Substitution of components may im...

Page 19: ...nd common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to...

Page 20: ...ue to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well g...

Page 21: ...e corresponding PORT ALARM Dip Switch is set to ON is not properly connected OR 3 EDS 405 becomes the Ring Master of this Turbo Ring after the Turbo Ring was broken If none of these 3 conditions occur...

Page 22: ...ils the other live source acts as a backup and automatically supplies all of Moxa EDS 405 s power needs Communication Connections EDS 405 MM SC ST has 3 10 100BaseT X Ethernet ports and 2 100BaseFX mu...

Page 23: ...ugh Cable Wiring Straight Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector Tx Tx Rx Rx Cable Wiring 3 3 6 6 1 1 2 2 NIC Port Rx Rx Tx Tx RJ45 8 pin to RJ45 8 pin Cross Over Cabl...

Page 24: ...or full duplex transmission All you need to remember is to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of d...

Page 25: ...Wiring EDS 405 ATTENTION This is a Class 1 Laser LED product Do not stare directly into the Laser LED beam 3 9...

Page 26: ...eas some will want to make full use of EDS 405 s advanced device management functions This chapter includes the following sections Supported Ethernet Network Topologies Redundant Ring Topology Star Wi...

Page 27: ...ets from traveling through any of the network s redundant loops In the event that one branch of this ring becomes disconnected from the rest of the network the Turbo Ring protocol automatically readju...

Page 28: ...ASTER EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING MASTER EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING MASTER NOTE EDS 405 is a switch with plug and play ring redundancy Ports 4 and 5 are design...

Page 29: ...then those EDS 405s whose Dip Switch 6 is set to ON will auto negotiate to determine which one will be the Ring Master If you don t enable any EDS 405 to be the Ring Master by setting Dip Switch 6 to...

Page 30: ...port 4 or 5 of the adjacent EDS 405 When the number of EDS units in the Turbo Ring is even If there are 2N EDS units an even number in the Turbo Ring then the backup segment is one of the two segment...

Page 31: ...LT RING MASTER EDS 2 EDS 2N 1 EDS N 2 EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING MASTER port 4 5 port 4 5 port 4 5 port 4 5 port 4 5 port 4 5 EDS N EDS 405 1 2 3 4 5 10M 100M PWR1 PWR2 FAULT RING...

Page 32: ...nd the port s link is active or when the corresponding PORT alarm is disabled On When the EDS 405 is the Master of this Turbo Ring RING MASTER Green Blinking When the EDS 405 is Ring Master of the Tur...

Page 33: ...o Ring topology and enable the Turbo Ring break alarm If the EDS 405 is the Master of this Turbo Ring and the Turbo Ring is broken the relay will form an open circuit Set to Off P1 P5 Disables the cor...

Page 34: ...o negotiate to determine which one will be the Ring Master Upgrading the Firmware Follow the procedures given below to upgrade EDS 405 s firmware 1 Download the EDS 405 Utility zip file from www moxa...

Page 35: ...you just downloaded 8 Locate the EDS 405 rom file and click on OPEN to start upgrading the new version of the firmware 9 After the firmware has been upgraded click on OK to refresh the information dis...

Page 36: ...ort is required to cascade to another switch and you must swap the pin assignments by setting a dip switch to MDI X mode With auto MDI MDI X you can cascade from any port and use either a straight thr...

Page 37: ...eries are plug and play devices so that software configuration is not required at installation or during maintenance Switching Filtering and Forwarding Each time a packet arrives at one of the switche...

Page 38: ...ress buffer power down the unit and then power it back up Auto Negotiation and Speed Sensing All of EDS 405 s RJ45 Ethernet ports independently support auto negotiation for 10BaseT and 100BaseTX modes...

Page 39: ...ontact One relay output with current carrying capacity of 1A 24 VDC RJ45 Ports 10 100BaseT x auto negotiation speed F H duplex mode and auto MDI MDI X connection Fiber Ports 100BaseFX ports SC ST conn...

Page 40: ...re 0 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety UL60950 E212360 UL...