EDS-2008-EL/ELP Series 

Quick Installation Guide 

Moxa EtherDevice Switch 

Version 1.0, October 2019 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2019 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for EDS-2008-EL Series

Page 1: ...m support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3...

Page 2: ...allows users to enable or disable broadcast storm protection BSP Quality of Service QoS function via the DIP switches on the top panel The EDS 2008 EL ELP switches can be easily installed with DIN ra...

Page 3: ...event network devices from crashing Rugged Design Operating temperature range from 10 to 60 C or extended operating temperature from 40 to 75 C only available for the T models in the EL Series IP40 ru...

Page 4: ...4 Panel Layout of EDS 2008 EL EDS 2008 ELP 1 Chassis ground screw 2 Terminal block for power input 3 DIP switch 4 Power LED 5 10 100 BaseT X Port 6 10 100 BaseT X Port LED 7 Port number 8 Model name...

Page 5: ...rew 2 Terminal block for power input 3 DIP switch 4 Power LED 5 10 100 BaseT X Port 6 10 100 BaseT X Port LED 7 Port number 8 10 100 BaseFX Multi mode ST Port only for ST models 9 10 100 BaseFX Multi...

Page 6: ...6 Mounting Dimensions EDS 2008 EL Series EDS 2008 ELP Series...

Page 7: ...7 EDS 2008 EL M ST Series EDS 2008 EL M SC Series...

Page 8: ...he bottom of the DIN rail kit and pull down Suggested Removal Method STEP 1 Pull down the latch on the DIN rail kit with a screwdriver STEP 2 Slightly pull the device forward and lift up to remove it...

Page 9: ...than 3 5 mm in diameter as shown in the figure at the right NOTE Before tightening screws into the wall make sure the screw head and shank size are suitable by inserting the screw into one of the key...

Page 10: ...should also pay attention to the following items Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at th...

Page 11: ...nnector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on the EDS s top panel NOTE The power source comes from secondary circuits These cir...

Page 12: ...nnection The concept behind the SC ST port and cable is quite straightforward Suppose you are connecting devices I and II As opposed to electrical signals optical signals do not require a circuit in o...

Page 13: ...h Setting Description Quality of Service QoS ON Enable the Quality of Service to handle packet priorities in four WRR queues QoS priority mapping matrix in each queue QoS 3bit priority 7 6 5 4 3 2 1 0...

Page 14: ...o negotiates with the connected device for the fastest data transmission rate supported by both devices The EDS is a plug and play device so software configuration is not required at installation or d...

Page 15: ...or 100 Mbps transmission speeds with the device at the other end of the cable expected to advertise similarly Depending on what type of device is connected this will result in agreement to operate at...

Page 16: ...nmental Limits Note For indoor use only Operating Temperature 10 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F only available for the T models in the EL Series Storage Temperature 40 to 85 C 40 to 185 F...