PCI Express Boards 

Programming Guide 

 

6-5 

Control Serial Interface and Termination Resistor for MUE chips 

For Moxa boards that use MUE250, MUE450, and MUE850 chips, BAR2, which allocates 16 bytes, is the vector 
base address that can be used to control serial interface and termination resistors according to the following 
table. 

Offset 

Bit 

Port # 

Parameters 

0x4 

[3..0] 

0x0 : RS-232 
0x1 : RS-422 
0xF : RS-485 2W 
0xB : RS-485 4W 

[7..4] 

0x5 

[3..0] 

[7..4] 

0x6 

[3..0] 

[7..4] 

0x7 

[3..0] 

[7..4] 

0x8 

[7..0] 

[8..1] 

GPIO – Input 

0x9 

[7..0] 

[8..1] 

GPIO direction configuration 
0 : Set GPIO direction to input 
1 : Set GPIO direction to output 

0xA 

[7..0] 

[8..1] 

GPIO – Output (Termination Resistor) 
0 : Low (0 Ohm) 
1 : High (120 Ohm) 

 

Especially, the interfaces of 4 ports model, such as

 

CP-114EL and CP-114EL-I,

 

are using the following offset to 

set the interface of port 4. 
 

Offset 

Bit 

Port # 

Parameters 

0x4 

[3..0] 

0x0 : RS-232 
0x1 : RS-422 
0xF : RS-485 2W 
0xB : RS-485 4W 

[7..4] 

0x5 

[3..0] 

[7..4] 

0x6 

[3..0] 

[7..4] 

0x7 

[3..0] 

 

For Baud Rate Setting 

For General PC Com Port: CLK=1.8432MHz 
 

Div = CLK/(Baud x 16) 

 
But for Moxa Board: CLK=

14.7456

MHz 

 

Div = 

CLK

/(Baud x 16) 

www.ipc2u.ru

www.ipc2u.com

www.moxa.pro

Summary of Contents for CP-114EL-I

Page 1: ...PCI Express Board User s Manual Edition 11 2 October 2017 www moxa com product 2017 Moxa Inc All rights reserved www ipc2u ru www ipc2u com www moxa pro ...

Page 2: ...o the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsibility for its use or for any infringements on the rights of third parties that may result from its use This product might include unintentional technical or typographical errors Changes are periodically made to the info...

Page 3: ... 3 11 DOS 3 11 Linux 32 bit 64 bit 3 14 SCO 3 15 4 Configuring Intelligent RS 485 4 1 Windows Users 4 2 Linux Users 4 5 5 Serial Programming Tools 5 1 Moxa PComm 5 2 Installing PComm 5 2 PComm Programming Library 5 2 Utilities 5 2 Diagnostics for Moxa boards only 5 2 Monitor for Moxa boards for Windows 2000 XP 2003 Vista 2008 7 x86 and x64 5 3 Terminal Emulator 5 4 RS 485 Programming 5 4 ADDC 5 4 ...

Page 4: ...A I 7 15 Board Side Pin Assignments Female DB44 7 15 Device Side Pin Assignments Male DB9 7 16 Male DB25 CBL M44M25x4 50 7 16 CP 116E A 7 17 Board Side Pin Assignments Female SCSI VHDCI68 7 17 Device Side Pin Assignments Male DB9 7 17 Male DB25 OPT8B CBL M68M25x8 100 7 17 Female DB25 OPT8A S 7 18 8 Troubleshooting 8 1 A Product Specifications A 1 CP 118EL A Specifications A 2 CP 168EL A Specificat...

Page 5: ...ts to connect data acquisition equipment and other serial devices to a PC The following topics are covered in this chapter Overview PCI Express Solution ESD Protection ADDC Automatic Data Direction Control for RS 485 Operating System Support Moxa Serial Comm Tool Intelligent RS 485 Applications Features Package Checklist Installation Flowchart www ipc2u ru www ipc2u com www moxa pro ...

Page 6: ...htning or high potential voltage The surge protection feature makes the PCI Express boards suitable for industrial factory type applications and for use with applications that are subject to severe weather conditions ADDC Automatic Data Direction Control for RS 485 RS 485 uses differential data transmission over two wires to transmit data from one station to another and allows multiple transmitter...

Page 7: ...ferent applications including Internet Intranet Connections Remote Access Multi user Applications Industrial Automation Office Automation Telecommunications PC based Vending Machines and Kiosks POS Point of Sale Systems Features The PCI Express boards have the following outstanding features PCI Express 1 compliant Low profile board for compact sized PCs Data flow LED display onboard 128 byte FIFO ...

Page 8: ...o tuning Chapter 4 Intelligent RS 485 Setting Restart the system and check the driver initialization status Chapter 3 Software Installation Connect the serial devices to the PCI Express board s serial ports Chapter 6 Pin Assignments Install the drivers and configure the boards and ports Chapter 3 Software Installation Install the boards in PCI Express expansion slots Chapter 2 Hardware Installatio...

Page 9: ...he board before installing the driver driver installation is discussed in Chapter 3 The following topics are covered in this chapter CP 118EL A Dimensions CP 168EL A Dimensions CP 104EL A Dimensions CP 102E Dimensions CP 102EL Dimensions CP 132EL Dimensions CP 132EL I Dimensions CP 114EL Dimensions CP 114EL I Dimensions CP 116E A Dimensions CP 134EL A I Dimensions CP 118E A I 138E A I Dimensions P...

Page 10: ...PCI Express Boards Hardware Installation 2 2 CP 118EL A Dimensions CP 168EL A Dimensions www ipc2u ru www ipc2u com www moxa pro ...

Page 11: ...PCI Express Boards Hardware Installation 2 3 CP 104EL A Dimensions CP 102E Dimensions www ipc2u ru www ipc2u com www moxa pro ...

Page 12: ...PCI Express Boards Hardware Installation 2 4 CP 102EL Dimensions CP 132EL Dimensions www ipc2u ru www ipc2u com www moxa pro ...

Page 13: ...PCI Express Boards Hardware Installation 2 5 CP 132EL I Dimensions CP 114EL Dimensions www ipc2u ru www ipc2u com www moxa pro ...

Page 14: ...PCI Express Boards Hardware Installation 2 6 CP 114EL I Dimensions CP 116E A Dimensions www ipc2u ru www ipc2u com www moxa pro ...

Page 15: ...PCI Express Boards Hardware Installation 2 7 CP 134EL A I Dimensions CP 118E A I 138E A I Dimensions www ipc2u ru www ipc2u com www moxa pro ...

Page 16: ...Step 4 Plug the PCI Express board firmly into a free PCI Express slot Step 5 Fasten the holding screw to fix the control board in place Step 6 Replace the PC s cover Step 7 Power on the PC The BIOS will automatically set the IRQ and I O address NOTE Each Moxa PCI Express board uses one unique IRQ and I O address both of which are assigned automatically by the PCI BIOS Step 8 Proceed with the softw...

Page 17: ... previous chapter Hardware Installation Refer to the next chapter Serial Programming Tools for information about developing your own serial programming applications Note that you can install up to 8 PCI Express boards in one system provided sufficient I O address and IRQ number resources are available You can download the drivers from the Moxa website The following topics are covered in this chapt...

Page 18: ...llation chapter for details Turn on your PC Windows will automatically detect the board Install the driver from the Documentation and Software CD See the Installing the Driver subsection in this chapter for detailed instructions Configure the board s ports See the Configuring the Ports subsection in this chapter for detailed instructions The PCI Express board and ports are ready to use Driver alre...

Page 19: ...h Windows 7 First make sure that you have already plugged the board or boards into the system s PCI Express slot s NOTE If you have already installed Moxa s PCI Express board in your computer and you are installing additional boards Windows 7 will automatically detect and install the new board s the next time you boot up the computer In this case proceed directly to the next section Configuring th...

Page 20: ...ware Installation 3 4 3 Click Next to install the driver in the indicated folder or use the drop down menu to locate a different folder 4 Click Install to proceed with the installation www ipc2u ru www ipc2u com www moxa pro ...

Page 21: ...s section we describe how to access MOXA Smartio Industio Window Driver and lead you to do the serial port configuration Accessing MOXA Smartio Industio Window Driver Configuring Serial Port Port Number Rx TX FIFO Interface and Termination Resistor Accessing MOXA Smartio Industio Window Driver Expand the Multi port serial adapters tab right click CP 114EL Series PCI Express Bus and then click Prop...

Page 22: ...rt Setting 2 Select a COM number for the port from the Port Number pull down list Select the Auto Enumerating COM Number option to map subsequent ports automatically The port numbers will be assigned in sequence For example if COM 1 is assigned to Port 1 then COM 2 if not already occupied will be assigned to Port 2 etc www ipc2u ru www ipc2u com www moxa pro ...

Page 23: ...face and Termination Resistor If you are using CP 118EL A CP 114EL CP 114EL I CP 132EL or CP 132EL I select Interface RS 232 RS 422 RS 485 2W or RS 485 4W and Termination Resistor 120Ω Enable or Disable for configuration For illustration purposes we use the CP 114EL The following figure shows the settings for configuring the port for RS 422 and disabling Termination Resistor 2 Click OK to save the...

Page 24: ... To start the program click Start Programs MOXA PComm Lite Version 1 X PComm Diagnostic NOTE You can download the PComm Lite software for free from Moxa s website at www moxa com support free_downloads htm www ipc2u ru www ipc2u com www moxa pro ...

Page 25: ...use the mouse to place the cursor over MOXA CP 114EL Series PCI Express Bus under Multi port serial adapters Right click and select the Uninstall option 2 Select Delete the driver software for this device and click OK to proceed with uninstalling the board www ipc2u ru www ipc2u com www moxa pro ...

Page 26: ...allation 3 10 Uninstalling the Driver The MSB driver may be removed through Add Remove Programs in the Windows Control Panel Click Uninstall next to MOXA Smartio Industio Windows Driver Verx xx www ipc2u ru www ipc2u com www moxa pro ...

Page 27: ...ds CP 102E CP 102EL CP 132EL CP 132EL I CP 104EL A CP 114EL CP 114EL I CP 118EL A CP 168EL A CP 118E A I CP 138E A I CP 134EL A I CP 116E A WARNING If you are using a Serial ATA HDD for DOS the installation process will hang To prevent the installation process from hanging change your HDD to an IDE drive NOTE The following procedure shows how to install the CP 168EL driver for DOS Installing the D...

Page 28: ...f the setup program s most frequently used functions For complete details press F1 to open the online help file 1 Run BIN SETUP EXE 2 Press Enter to select the model name of the Moxa board you are installing 3 A window will open displaying basic configuration information for all boards of this type currently installed in the system Press PgDn to configure the port settings www ipc2u ru www ipc2u c...

Page 29: ...a port You can set the port numbers to any number between 0 and 255 inclusive However you must ensure that you assign each port a unique port number If you are developing your own application software then you may want to select port numbers that take into consideration the structure of the program TxD buffer size The TxD buffer is the transmission output buffer allocated by the system for each po...

Page 30: ... using the API 232 library Unloading the Driver To unload release the driver from memory type DP DRV Q at the DOS prompt and then press Enter Linux 32 bit 64 bit Moxa provides drivers that allow you to use the following serial boards for Linux PCI Express Boards CP 118EL CP 168EL CP 104EL CP 102E CP 102EL CP 132EL CP 132EL I CP 114EL CP 114EL I CP 118E A I CP 138E A I CP 134EL A I CP 116E A NOTE T...

Page 31: ...E2 6 Use the Moxa diagnostics utility to verify the driver status cd moxa mxser utility diag msdiag 7 Use the Moxa terminal utility to test the tty ports cd moxa mxser utility term msterm SCO SCO OpenServer 5 SCO OpenServer 6 SCO UnixWare 7 Follow the steps given in this section to install the SCO OpenServer 5 6 SCO UnixWare 7 driver The installation procedures for SCO UnixWare 7 and SCO OpenServe...

Page 32: ...1 Smartio Industio Family Basic Configuration Board No Board Type I O Address Interrupt Bus Dev No 1 None 2 None 3 None 4 None PgDn getty Setting Enter Confirm Input Value Esc Exit Tab Change Item 7 The board s basic information such as I O address Bus No and Device No will be shown The SCO system will assign the resources automatically to the PCI Express board you selected 8 Next press Esc to exi...

Page 33: ... you how to manually configure other Moxa boards as well as non Moxa boards We use the CP 134EL A board to demonstrate how to use the Intelligent RS 485 tools for Windows 7 8 8 1 The basic procedure you should follow is illustrated in the following workflow diagram The following topics are covered in this chapter Windows Users Linux Users Use the Auto Tuning tool Use the Diagnosis tool Adjust non ...

Page 34: ...steps to use the Intelligent RS 485 function 1 Expand the Multi port serial adapters tab right click MOXA CP 134EL A Series PCI Express Bus and then click Properties to open the configuration panel 2 Double click the COM number you wish to configure www ipc2u ru www ipc2u com www moxa pro ...

Page 35: ...ings 4 Click OK on the Ports Configuration page to save the settings 5 Test if the communication is OK If it s not OK proceed to Step 6 6 Click on the COM Number click Auto Tuning next and then click OK The PCIe board will automatically detect the RS 485 environment and suggest the correct Bias Resistor and Termination Resistor Click OK to save the setting To apply the setting you need to click OK...

Page 36: ... High Low Resistor Adjust Terminator Resistor Waveform Distortion Too many devices Receive Reflect Signal Long distance Data Error Too many devices long distance NOTE The Diagnosis tool is extremely sensitive consequently it could indicate errors even if the communication status is OK In this case you can decide whether or not to make the suggested configuration changes 10 Repeat from Step 6 until...

Page 37: ... s OK nothing further needs to be done If it s not OK proceed with Step 3 3 Use the following command for the Auto Tuning process Enter Y to make the value effective immediately muestty a baud rate value dev ttyMUE1 4 Test if the communication is OK If it s OK nothing further needs to be done If it s not OK proceed with Step 5 5 Use the following command to run diagnosis muestty d baud rate value ...

Page 38: ...oo many devices Receive Reflect Signal Long distance Data Error Too many devices long distance NOTE The Diagnosis tool is extremely sensitive consequently it could indicate errors even if the communication status is OK In this case you can decide whether or not to make the suggested configuration changes 7 Repeat from Step 3 until the communication is OK www ipc2u ru www ipc2u com www moxa pro ...

Page 39: ...ons provide details about the installation the library and the utilities for various platforms The following topics are covered in this chapter Moxa PComm Installing PComm PComm Programming Library Utilities Diagnostics for Moxa boards only Monitor for Moxa boards for Windows 2000 XP 2003 Vista 2008 7 x86 and x64 Terminal Emulator RS 485 Programming ADDC www ipc2u ru www ipc2u com www moxa pro ...

Page 40: ... driver installed in your system See the Software Installation chapter for instructions on how to install the drivers After installing PComm click Start select Program Files and then the PComm Lite group to select from the list of utilities and documents PComm Programming Library The serial communication library helps you develop serial communications programs for any COM port that complies with t...

Page 41: ...rt status monitoring program allows you to monitor data transmission of selected Moxa COM ports The program monitors data transmission reception throughput and communication line status with data updated and displayed on the screen at regular time intervals Click a specific port to see a graph of the current communication parameters and status of that port To run the Monitor program click Start Pr...

Page 42: ...bles and Cable Wiring chapter for more details about using RS 485 The CP 118EL Series supports 2 wire half duplex RS 485 and 4 wire full duplex RS 485 communication Ports configured for 2 wire RS 485 use the Data and Data pins for both transmitting and receiving data Moxa s own ADDC Automatic Data Direction Control technology is used to switch between transmission and reception ADDC ADDC is the be...

Page 43: ...seful instruction The following topics are covered in this chapter Relative Product List Resource Requirement for Moxa Board PCI Configuration for Moxa Board UART Register Structure for MU860 chip UART Register Structure for MUE250 MUE450 and MUE850 chips For Baud Rate Setting Moxa Board PCI Device ID List UART Datasheet www ipc2u ru www ipc2u com www moxa pro ...

Page 44: ...Chip Address Offset Size IRQ All 0x3C IRQ Vector Address MU860 0x1C BAR3 16 bytes UART register I O Base Address MU860 0x18 BAR2 64 bytes UART register Memory Base Address MUE250 MUE450 MUE850 0x14 BAR1 4096 bytes Vector Base Address MUE250 MUE450 MUE850 0x18 BAR2 16 bytes Byte Offset 0 7 8 15 16 23 24 31 00h Vendor ID Device ID 04h Command Status 08h 0Ch 10h BAR0 14h BAR1 18h BAR2 1Ch BAR3 3Ch In...

Page 45: ...gister s I O address is 0x181 The second port s UART register s I O address is 0x180 2 1 8 0x188 The first register s I O register is 0x188 The second register s I O register is 0x189 IRQ Vector Register Structure Bit Value Status 0 Interrupt pending Please read the UART register to get the detail interrupt information 1 No interrupt pending All serial ports on the same Moxa board use the same IRQ...

Page 46: ...f the base address is 0x200 The first port s UART register s I O address is 0x200 1 1 0x200 0x200 The first register s I O address is 0x200 The second register s I O address is 0x201 The second port s UART register s I O address is 0x200 2 1 0x200 0x400 The first register s I O register is 0x400 The second register s I O register is 0x401 NOTE For CP 104EL A CP 114EL CP 114EL I and CP 134EL A only...

Page 47: ...0x7 3 0 7 7 4 8 0x8 7 0 8 1 GPIO Input 0x9 7 0 8 1 GPIO direction configuration 0 Set GPIO direction to input 1 Set GPIO direction to output 0xA 7 0 8 1 GPIO Output Termination Resistor 0 Low 0 Ohm 1 High 120 Ohm Especially the interfaces of 4 ports model such as CP 114EL and CP 114EL I are using the following offset to set the interface of port 4 Offset Bit Port Parameters 0x4 3 0 1 0x0 RS 232 0x...

Page 48: ...CP 114EL I 4 PCIe MUE450 921 6k 0x1393 0x1144 CP 134EL A 4 PCIe MUE450 921 6k 0x1393 0x1342 CB 114 4 PC 104 Plus MU860 921 6k 0x1393 0x1142 CB 134I 4 PC 104 Plus MU860 921 6k 0x1393 0x1341 CP 118U 8 UPCI MU860 921 6k 0x1393 0x1180 CP 118U I 8 UPCI MU860 921 6k 0x1393 0x1180 CP 138U 8 UPCI MU860 921 6k 0x1393 0x1380 CP 138U I 8 UPCI MU860 921 6k 0x1393 0x1380 CP 168U 8 UPCI MU860 921 6k 0x1393 0x16...

Page 49: ... DB25 Device Side Pin Assignments CP 132EL CP 132EL I Board Side Pin Assignments Female DB25 Device Side Pin Assignments CP 114EL CP 114EL I Board Side Pin Assignments Female DB44 Device Side Pin Assignments CP 118E A I CP 138E A I Board Side Pin Assignments Female DB78 Device Side Pin Assignments Male DB9 Male DB25 CBL M78M25x8 100 CP134EL A I Board Side Pin Assignments Female DB44 Device Side Pi...

Page 50: ...e RS 232 RS 422 4 wire RS 485 2 wire RS 485 OPT8B CBL M68M25x8 100 DB25 male OPT8A OPT8S DB25 female CP 118EL A The CP 118EL A board has a female SCSI VHDCI68 connector on the board with various connection options available for connecting from the board to your serial devices In this chapter we provide pin assignments for the board side connector as well as pin assignments for device side connecto...

Page 51: ...22 DCD2 34 RxD0 46 DTR5 58 DSR3 11 DSR4 23 DTR2 35 RxD7 47 DCD5 59 TxD3 12 DTR4 24 DSR2 36 CTS7 48 RTS5 60 GND RS 422 and 4 wire RS 485 Pin Signal Pin Signal Pin Signal Pin Signal 1 TxD6 B 18 TxD2 B 35 TxD7 B 52 TxD3 B 5 TxD6 A 22 TxD2 A 39 TxD7 A 56 TxD3 A 6 RxD6 A 23 RxD2 A 40 RxD7 A 57 RxD3 A 8 RxD6 B 25 RxD2 B 42 RxD7 B 59 RxD3 B 9 GND 26 GND 43 GND 60 GND 10 RxD4 B 27 RxD0 B 44 RxD5 B 61 RxD1...

Page 52: ...ta A 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 Male DB25 OPT8B CBL M68M25x8 100 Pin RS 232 RS 422 RS 485 4W RS 485 2W 2 TxD RxD B Data B 3 RxD TxD B 4 RTS 5 CTS 6 DSR 7 GND GND GND 8 DCD TxD A 20 DTR RxD A Data A Female DB25 OPT8A S Pin RS 232 RS 422 RS 485 4W RS 485 2W 2 RxD TxD B 3 TxD RxD B Data B 4 CTS 5 RTS 6 DTR RxD A Data A 7 GND GND GND 8 DCD TxD A 20 DSR www ipc2u ru www ipc2u com www moxa pro ...

Page 53: ... Pin Signal Pin Signal Pin Signal 1 RxD6 13 DCD4 25 TxD2 37 RI7 49 RI5 61 TxD1 2 CTS6 14 RTS4 26 GND 38 RTS7 50 CTS5 62 DSR1 3 RI6 15 RI4 27 TxD0 39 DCD7 51 RxD5 63 DTR1 4 RTS6 16 CTS4 28 DSR0 40 DTR7 52 RxD3 64 DCD1 5 DCD6 17 RxD4 29 DTR0 41 DSR7 53 CTS3 65 RTS1 6 DTR6 18 RxD2 30 DCD0 42 TxD7 54 RI3 66 RI1 7 DSR6 19 CTS2 31 RTS0 43 GND 55 RTS3 67 CTS1 8 TxD6 20 RI2 32 RI0 44 TxD5 56 DCD3 68 RxD1 ...

Page 54: ... CTS 5 RTS 6 DTR 7 GND 8 DCD 20 DSR CP 104EL A Board Side Pin Assignments Female DB44 RS 232 Port 1 Port 2 Port 3 Port 4 13 TxD 9 TxD 5 TxD 1 TxD 14 RxD 10 RxD 6 RxD 2 RxD 15 RTS 11 RTS 7 RTS 3 RTS 28 CTS 24 CTS 20 CTS 16 CTS 29 DTR 25 DTR 21 DTR 17 DTR 30 DSR 26 DSR 22 DSR 18 DSR 42 DCD 39 DCD 35 DCD 31 DCD 44 GND 41 GND 37 GND 33 GND www ipc2u ru www ipc2u com www moxa pro ...

Page 55: ... 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 Male DB25 CBL M44M25x4 50 Pin RS 232 2 TxD 3 RxD 4 RTS 5 CTS 6 DSR 7 GND 8 DCD 20 DTR CP 102E Board Side Pin Assignments Male DB9 The CP 102E has two male DB9 connectors onboard Male DB9 Pin RS 232 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 www ipc2u ru www ipc2u com www moxa pro ...

Page 56: ... Pin RS 232 1 13 2 DCD1 14 3 GND 15 DTR1 4 CTS1 16 DSR1 5 RxD1 17 RTS1 6 18 TxD1 7 19 8 20 9 DTR0 21 DCD0 10 DSR0 22 GND 11 RTS0 23 CTS0 12 TxD0 24 RxD0 Device Side Pin Assignments Male DB9 CBL M25M9x2 50 Pin RS 232 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 www ipc2u ru www ipc2u com www moxa pro ...

Page 57: ...B 18 RxD1 B 6 19 7 20 8 21 TxD0 A 9 RxD0 A 22 GND0 10 23 11 24 TxD0 B 12 RxD0 B 25 13 Pin Signal Pin Signal 1 14 2 15 Data1 A 3 GND1 16 4 17 5 18 Data1 B 6 19 7 20 8 21 9 Data0 A 22 GND0 10 23 11 24 12 Data0 B 25 13 Device Side Pin Assignments Male DB9 CBL M25M9x2 50 Pin RS 422 RS 485 4W RS 485 2W 1 TxD A 2 TxD B 3 RxD B Data B 4 RxD A Data A 5 GND GND 6 7 8 9 www ipc2u ru www ipc2u com www moxa p...

Page 58: ... 41 GND 6 RxD2 18 DSR3 30 DSR0 42 DCD0 7 RTS2 19 31 DCD3 43 8 20 CTS2 32 44 GND 9 TxD1 21 DTR2 33 GND 10 RxD1 22 DSR2 34 11 RTS1 23 35 DCD2 12 24 CTS1 36 RS 422 4 wire RS 485 Pin Signal Pin Signal Pin Signal Pin Signal 1 RxD3 13 RxD0 25 RxD1 37 GND 2 TxD3 14 TxD0 26 38 3 15 27 39 TxD1 4 16 28 40 5 RxD2 17 RxD3 29 RxD0 41 GND 6 TxD2 18 30 42 TxD0 7 19 31 TxD3 43 8 20 32 44 GND 9 RxD1 21 RxD2 33 GND...

Page 59: ...12 27 42 13 Data0 B 28 43 14 29 Data0 A 44 GND0 15 30 Device Side Pin Assignments Male DB9 CBL M44M9x4 50 Pin RS 232 RS 422 RS 485 4W RS 485 2W 1 DCD TxD A 2 RxD TxD B 3 TxD RxD B Data B 4 DTR RxD A Data A 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 Male DB25 CBL M44M25x4 50 Pin RS 232 RS 422 RS 485 4W RS 485 2W 2 TxD RxD B Data B 3 RxD TxD B 4 RTS 5 CTS 6 DSR 7 GND GND GND 8 DCD TxD A 20 DTR RxD A Data A 2...

Page 60: ...5 TXD6 25 44 DSR6 64 6 GND5 26 RTS5 45 CTS5 65 DCD5 7 TXD5 27 DTR5 46 DSR5 66 RXD5 8 28 RTS4 47 67 DCD4 9 GND4 29 DTR4 48 CTS4 68 RXD4 10 TXD4 30 49 DSR4 69 11 GND3 31 RTS3 50 CTS3 70 DCD3 12 TXD3 32 DTR3 51 DSR3 71 RXD3 13 33 RTS2 52 72 DCD2 14 GND2 34 DTR2 53 CTS2 73 RXD2 15 TXD2 35 54 DSR2 74 16 GND1 36 RTS1 55 CTS1 75 DCD1 17 TXD1 37 DTR1 56 DSR1 76 RXD1 18 38 RTS0 57 77 DCD0 19 GND0 39 DTR0 5...

Page 61: ...RXD2 53 73 TXD2 15 RXD2 35 54 74 16 GND1 36 55 75 TXD1 17 RXD1 37 RXD1 56 76 TXD1 18 38 57 77 TXD0 19 GND0 39 RXD0 58 78 TXD0 20 RXD0 59 RS 485 2W Pin Signal Pin Signal Pin Signal Pin Signal 1 GND7 21 40 60 2 DATA7 22 DATA7 41 61 3 23 42 62 4 GND6 24 DATA6 43 63 5 DATA6 25 44 64 6 GND5 26 45 65 7 DATA5 27 DATA5 46 66 8 28 47 67 9 GND4 29 DATA4 48 68 10 DATA4 30 49 69 11 GND3 31 50 70 12 DATA3 32 D...

Page 62: ...W RS 485 2W 1 DCD TxD A 2 RxD TxD B 3 TxD RxD B Data B 4 DTR RxD A Data A 5 GND GND GND 6 DSR 7 RTS 8 CTS Male DB25 CBL M78M25x8 100 PIN RS 232 RS 422 RS 485 4W RS 485 2W 2 TxD RxD B Data B 3 RxD TxD B 4 RTS 5 CTS 6 DSR 7 GND GND GND 8 DCD TxD A 20 DTR RxD A Data A www ipc2u ru www ipc2u com www moxa pro ...

Page 63: ...37 GND3 8 23 38 9 RXD2 24 39 TXD2 10 TXD2 25 RXD2 40 11 26 41 GND2 12 27 42 TXD1 13 RXD1 28 43 14 TXD1 29 RXD1 44 GND1 15 30 RS 485 4W Pin Signal Pin Signal Pin Signal 1 RXD4 16 31 TXD4 2 TXD4 17 RXD4 32 3 18 33 GND4 4 19 34 5 RXD3 20 35 TXD3 6 TXD3 21 RXD3 36 7 22 37 GND3 8 23 38 9 RXD2 24 39 TXD2 10 TXD2 25 RXD2 40 11 26 41 GND2 12 27 42 TXD1 13 RXD1 28 43 14 TXD1 29 RXD1 44 GND1 15 30 www ipc2u...

Page 64: ...2 27 42 13 DATA1 28 43 14 29 DATA1 44 15 30 Device Side Pin Assignments Male DB9 PIN RS 232 RS 422 RS 485 4W RS 485 2W 1 DCD TxD A 2 RxD TxD B 3 TxD RxD B Data B 4 DTR RxD A Data A 5 GND GND GND 6 DSR 7 RTS 8 CTS Male DB25 CBL M44M25x4 50 PIN RS 232 RS 422 RS 485 4W RS 485 2W 2 TxD RxD B Data B 3 RxD TxD B 4 RTS 5 CTS 6 DSR 7 GND GND GND 8 DCD TxD A 20 DTR RxD A Data A www ipc2u ru www ipc2u com w...

Page 65: ... 7 DSR6 19 CTS2 31 RTS0 43 GND 55 RTS3 67 CTS1 8 TxD6 20 32 44 TxD5 56 DCD3 68 RxD1 9 GND 21 RTS2 33 CTS0 45 DSR5 57 DTR3 10 TxD4 22 DCD2 34 RxD0 46 DTR5 58 DSR3 11 DSR4 23 DTR2 35 RxD7 47 DCD5 59 TxD3 12 DTR4 24 DSR2 36 CTS7 48 RTS5 60 GND Device Side Pin Assignments Male DB9 PIN RS 232 RS 422 RS 485 4W RS 485 2W 1 DCD TxD A 2 RxD TxD B 3 TxD RxD B Data B 4 DTR RxD A Data A 5 GND GND GND 6 DSR 7 ...

Page 66: ...rds Pin Assignments 7 18 Female DB25 OPT8A S PIN RS 232 RS 422 RS 485 4W RS 485 2W 2 RxD TxD B 3 TxD RxD B Data B 4 CTS 5 RTS 6 DTR RxD A Data A 7 GND GND GND 8 DCD TxD A 20 DSR www ipc2u ru www ipc2u com www moxa pro ...

Page 67: ...ed correctly Refer to the Pin Assignments chapter for correct cable connections b The cable or the board could be defective Try other ports cables or boards to verify this or use the PComm Diagnostic utility to test the Moxa board and port conditions If the Diagnostic program reports an error replace the faulty components Software Causes and Solutions a PCI Express Series boards will check the lin...

Page 68: ...P 168EL A Specifications CP 104EL A Specifications CP 102E Specifications CP 102EL Specifications CP 132EL Series Specifications CP 114EL Series Specifications CP 118E A I Specifications CP 138E A I Specifications CP 134EL A I Specifications CP 116E A Specifications www ipc2u ru www ipc2u com www moxa pro ...

Page 69: ...bps to 921 6 kbps Configuration Data Bits 5 6 7 8 Stop Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 1285 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Standards and Certificatio...

Page 70: ...Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 1225 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Standards and Certifications EN55032 EN55024 EN61000 3 2 EN61000 3 3 IEC 61000 4 ...

Page 71: ...Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 805 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Standards and Certifications EN55032 EN55024 EN61000 3 2 EN61000 3 3 IEC 61000 4 2...

Page 72: ...p Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Environment Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Standards and Certifications EN55032 EN55024 EN61000 3 2 EN61000 3 3 EN61000 6 2 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4...

Page 73: ...p Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Environment Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Standards and Certifications EN55032 EN55024 EN61000 3 2 EN61000 3 3 EN61000 6 2 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4...

Page 74: ...Data Bits 5 6 7 8 Stop Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control XON XOFF Environment Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Optical Isolation 2 kV only for CP 132EL I Standards and Certifications EN55032 EN55024 EN61000 3 2 EN61000...

Page 75: ... Configuration Data Bits 5 6 7 8 Stop Bits 1 1 5 2 I O address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Environment Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Optical Isolation 2 kV only for CP 114EL I Standards and Certifications EN55032 EN55...

Page 76: ...figuration Data Bits 5 6 7 8 Stop Bits 1 1 5 2 I O Address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 2356 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Surge Protection 4 kV Standards and Certificati...

Page 77: ...s 5 6 7 8 Stop Bits 1 1 5 2 I O Address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 2356 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Surge Protection 4 kV Standards and Certifications EN55032 EN55024...

Page 78: ...s 5 6 7 8 Stop Bits 1 1 5 2 I O Address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 3414 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F ESD Protection Embedded 15 kV ESD Protection Surge Protection 4 kV Standards and Certifications EN55032 EN55024...

Page 79: ...Configuration Data Bits 5 6 7 8 Stop Bits 1 1 5 2 I O Address IRQ BIOS assigned Parity None Even Odd Space Mark Flow Control RTS CTS XON XOFF Power and Environment Power Requirement 2733 mA 3 3V Operating Temperature 0 to 55 C 32 to 132 F Operating Humidity 5 to 95 RH Storage Temperature 20 to 85 C 4 to 185 F Surge Protection 4 kV ESD Protection Embedded 15 kV ESD Protection Standards and Certific...

Reviews: