PCI Express Boards
Software Installation
3-15
5.
For the CP-132EL, CP-132EL-I, CP-114EL, CP-114EL-I, use the Moxa Port Configuration Tool to set
Interface and Termination Resistor for the MUE series. The MUE series includes CP-102E, CP-102EL,
CP-132EL, CP-132EL-I, CP-114EL and CP-114EL-I.
Usage: muestty <operation> device
Device: The MUE series device node
Operation:
-h
Help
-g
Get interface and terminator type
-i intf
Set interface type with options below
-t value
Set termination resistor with options below
intf
RS232
RS-232 mode
RS422
RS-422 mode
RS4852W
RS-485 2-wire mode
RS4854W
RS-485 4-wire mode
value
NONTERM
Non termination resistor
120TERM
120-ohm termination resistor
For example:
To set the MUE interface
# muestty –i RS422 /dev/ttyMUE2
To set the MUE termination resistor
# muestty –t 120TERM /dev/ttyMUE2
6.
Use the Moxa diagnostics utility to verify the driver status:
#cd /moxa/mxser/utility/diag
#./msdiag
7.
Use the Moxa terminal utility to test the tty ports:
#cd /moxa/mxser/utility/term
#./msterm
SCO
•
SCO OpenServer 5
•
SCO OpenServer 6
•
SCO UnixWare 7
Follow the steps given in this section to install the SCO OpenServer 5/6 & SCO UnixWare 7 driver. The
installation procedures for SCO UnixWare 7 and SCO OpenServer 5/6 are similar.
1.
Copy the driver file
.tar
to your host.
2.
#tar xvf <driver tar file>
#/tmp/moxa/mxinstall
3.
The window shown below will open next. Press RETURN to continue.
=============================================================
Copyright© 2008 Moxa Inc.
All Rights Reserved.
Moxa Smartio/Industio Family Device Driver Installation (Ver. 1.11)
=============================================================
For SCO UnixWare 7
Tar files, please wait.....O.K.
Press RETURN to continue
NOTE
If your environment is SCO OpenServer 5/6, you can skip steps 4 and 5.
4.
When you see the screen below, select “Esc” to exit and reboot your computer.
MOXA Smartio/Industio Family Installation Utility (Ver 1.11)
www.ipc2u.ru
www.ipc2u.com
www.moxa.pro