CN2510
Setting Up Raw UDP
6-4
Configuring RAW UDP Mode
1.
Move the cursor to the
Description/more setting
column, and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
------------------------------------------------------------------------------
[Mode]
Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application
Mode
Description/more setting
01 [NT Real COM
] [ASPP ]
[Async Server Proprietary Protocol]
02 [NT Real COM
] [ASPP ]
[Async Server Proprietary Protocol]
03 [NT Real COM
] [ASPP ]
[Async Server Proprietary Protocol]
04 [NT Real COM
] [ASPP ]
[Async Server Proprietary Protocol]
05 [NT Real COM
] [ASPP ]
[Async Server Proprietary Protocol]
06 [Raw UDP
] [RAW UDP ]
[
Pure raw data (UDP) mode
]
07 [NT Real COM
] [ASPP ]
[Async Server Proprietary Protocol]
2.
The pop-up selector contains input/display fields for
serial to LAN
and
LAN to serial
parameters,
Local
Listen Port
,
Delimiter 1 (Hex)
,
Delimiter 2 (Hex)
, and
Force transmit (ms)
. Each item is described
in detail below the figure.
+--------------------------------------------------------------+
|
Begin
End
Port
|
| (serial to LAN)
|
| Dest. IP addr 1 [
][
][
] |
| Dest. IP addr 2 [
][
][
] |
| Dest. IP addr 3 [
][
][
] |
| Dest. IP addr 4 [
][
][
] |
| (LAN to serial)
|
| Src. IP addr 1 [
][
]
|
| Src. IP addr 2 [
][
][
] |
| Src. IP addr 3 [
][
][
] |
| Src. IP addr 4 [
][
][
] |
|
|
| Local Listen Port
: [
]
|
| Delimiter 1 (Hex)
: [ ]
|
| Delimiter 2 (Hex)
: [ ]
|
| Force transmit (ms)
: [
]
|
+--------------------------------------------------------------+
Setting
Value
Notes
Necessity
Dest. IP
address
1/2/3/4
Begin:
x.x.x.x
End:
y.y.y.y
Port:
1 to 65535
Defines 1 to 4 groups of IP addresses. UDP packets
will be sent through UDP port
Port
to the range of IP
addresses from the
Begin
IP address to the
End
IP
address.
1: Required
(2, 3, 4 are
Optional)
Src. IP
address
1/2/3/4
Begin:
x.x.x.x
End:
y.y.y.y
Port:
1-65535
Defines IP addresses that will be allowed to transmit
UDP packets to CN2510’s Ethernet port. UDP
packets from IP addresses in the range from
Begin
IP address to
End
IP address will be accepted
through UDP port
Port
.
1: Required
(2, 3, 4 are
Optional)
Local
Listen Port
1-65535
The UDP port that CN2510 listens to and that other
devices must use to contact CN2510. The default is
blank. Be sure to choose a Local Listen Port number
that does not conflict with the Local Listen Port for
CN2510’s other serial ports.
Required