Ds230_03a_oi_e.doc / Jun-15
Page 35 / 100
6.5.
„Operational Mode“ = 0 (DS23x)
Mode
0
Sensor1
[X6 | SINCOS IN 1]
SinCos encoder
(SIN+, SIN-, COS+, COS-)
Sensor2
[X7 | SINCOS IN 2]
SinCos encoder
(SIN+, SIN-, COS+, COS-)
Control1
[X10 | CONTROL IN]
HTL/PNP control signal
(complementary)
Control2
[X10 | CONTROL IN]
HTL/PNP control signal
(complementary)
Achievable
Safety Level
Speed
SIL3 / PLe
Direction
SIL3 / PLe
Standstill
SIL3 / PLe
This mode (only DS23x) is used to evaluate a dual channel system, equipped with two SinCos
sensors resp. Encoders, which must be performed in accordance to chapter
5.3
.
In this operational mode a DS230 variant reproduces always the input frequency at
[X6 | SINCOS IN 1] to the splitter output [X5 | SINCOS OUT].
A DS230 variant reproduces selectively the input frequency of Sensor1 or Sensor2
to the splitter output [X4 | RS422 OUT].
The inputs at terminal [X8 | RS422 IN 1] and [X9 | RS422 IN 2] have no function.
At terminal [X10 | CONTROL IN] the inputs Control1 and Control2 are available
for control signals..