C - 5
C.1.2.2 Access Ports are Not Responding
Access Ports are not responding. The table below provides suggestions to troubleshoot this issue.
C.1.2.3 Sensor Port frequently goes up and down
C.1.3 Mobile Unit Issues
This section describes various issues that may occur when working with the mobile units associated with the wireless
switch or associated Access Ports. Possible issues include:
•
Access Port Adopted, but MU is Not Being Associated
•
MUs Cannot Associate and/or Authenticate with Access Ports
•
Poor Voice Quality Issues
Country code for switch
is not set
Verify the country code is entered into the switch prior to adopting any
Access Ports. The switch is not fully functional until a country code is set.
Access ports are off-
network
Verify the Access Ports are connected to the network and powered on.
Access ports are
restricted in
configuration
Verify the switch is not configured with an access control list that does
not allow Access Port adoption; verify that Access Port adoption is not set
to “deny”.
Ensure that the Access Port adoption policy is added with a WLAN.
Access Port is on Exclude
List
Verify the Motorola Solutions RF Series Switch ACL adoption list does not
include the Access Ports that are not being adopted.
Miscellaneous other
issues
• With a packet sniffer, look for 8375 (broadcast) packets
• Reset the Motorola Solutions RF Series Switch. If the switch is hung, it
may begin to adopt Access Ports properly once it has been reset.
All else...
Contact Motorola Solutions Support.
Possible Problem
Suggestions to Correct
Access Port not
responding after
converting to a Detector
AP
When converting an AP300 to an Intrusion Detection Sensor, the
conversion requires approximately 60 seconds.
All else...
Contact Motorola Solutions Support.
Possible Problem
Suggestions to Correct
Sensor Port flapping
(going up and down)
This may be caused by the sensor being unable to find its server. Ensure
that the detection configuration is correct and that all cables are secure.
All else...
Contact Motorola Solutions Support.
Possible Problem
Suggestions to Correct
Summary of Contents for WiNG 4.4
Page 1: ...Motorola Solutions WiNG 4 4 SYSTEM REFERENCE GUIDE ...
Page 2: ......
Page 3: ...MOTOROLA SOLUTIONS WING 4 4 SYSTEM REFERENCE GUIDE 72E 157062 01 Revision A January 2012 ...
Page 6: ...iv WiNG 4 4 Switch System Reference Guide ...
Page 14: ...xii WiNG 4 4 Switch System Reference Guide ...
Page 48: ...1 32 WiNG 4 4 Switch System Reference Guide ...
Page 58: ...2 10 WiNG 4 4 Switch System Reference Guide ...
Page 280: ...4 176 WiNG 4 4 Switch System Reference Guide ...
Page 352: ...5 72 WiNG 4 4 Switch System Reference Guide ...
Page 476: ...6 124 WiNG 4 4 Switch System Reference Guide ...
Page 506: ...7 30 WiNG 4 4 Switch System Reference Guide ...
Page 532: ...8 26 WiNG 4 4 Switch System Reference Guide ...
Page 536: ...A 4 WiNG 4 4 Switch System Reference Guide ...
Page 544: ...B 12 WiNG 4 4 Switch System Reference Guide ...
Page 558: ...B 26 WiNG 4 4 Switch System Reference Guide ...
Page 574: ...C 16 WiNG 4 4 Switch System Reference Guide ...
Page 596: ...E 4 WiNG 4 4 Switch System Reference Guide ...
Page 597: ......