Required Equipment
MVME162/D2
1-9
1
test at power-up feature which verifies the integrity of the system. Various
162Bug routines that handle I/O, data conversion, and string functions are
available to user programs through the TRAP #15 system calls.
N
ote
MVME162Bug occupies the first half (512KB) of Flash
memory.
MVME712 Series Transition Modules
The MVME712 series transition modules provide an interface between the
MVME162 and peripheral devices such as EIA-232-D serial devices, SCSI
devices, and LAN Ethernet devices. A P2 Adapter Board or LCP2 Adapter
Board and cable are required.
C
aution
Connect peripheral devices to MVME712 serial ports 2 and
4 only. (Serial port 2 is the terminal or bug interface.) Do
not connect peripheral devices to serial ports 1 and 3, or to
the printer port.
An I/O device may be connected to serial port 1 (or 2) on the
MVME162 or to serial port 2 (or 4) on the MVME712, but not
to both ports. (That is, if an I/O device is connected to
MVME162 port 1, no other I/O device should be connected
to MVME712 port 2; they are functionally the same port.)
Available Software
Available software for the MVME162 includes the on-board
debugger/monitor firmware, VMEexec driver packages for various
IndustryPack modules, and numerous third-party applications for MC680x0-
based systems. Contact your local Motorola sales office for more information.
Summary of Contents for MVME162
Page 1: ...MVME162 Embedded Controller User s Manual MVME162 D2 ...
Page 6: ......
Page 10: ...x ...
Page 12: ...xii ...
Page 14: ...xiv ...
Page 52: ...Hardware Preparation and Installation 2 26 MVME162 Embedded Controller User s Manual 2 ...
Page 64: ...Operating Instructions 3 12 User s Manual 3 This page intentionally left blank ...
Page 78: ...Operating Instructions 3 26 User s Manual 3 ...
Page 92: ...Functional Description 4 14 User s Manual 4 Figure 4 1 MVME162 Main Module Block Diagram ...