Installation
22
68P81096E37-N
06/28/05
P1, P5, P8, P9
Country
Reference
Impedance
A *
B
C
D
E
P3, P7
Australia
√
√
Spain
√
√
Austria
√
√
Germany (2-wire)
√
√
Luxemburg
√
√
South Africa
√
√
Switzerland
√
Belgium
√
√
Cyprus
√
√
Former USSR
√
√
Former Yugoslavia
√
√
Germany (4-wire)
√
√
Greece
√
√
Italy
√
√
Netherlands
√
√
Portugal
√
√
Denmark
√
√
Ireland
√
√
UK
√
√
Finland
√
√
France
√
√
Norway
√
Sweden
√
820
Ω
120
η
F
220
Ω
820
Ω
115
η
F
220
Ω
830
Ω
72
η
F
150
Ω
600
Ω
500
Ω
330
η
F
400
Ω
620
Ω
310
η
F
370
Ω
820
Ω
115
η
F
220
Ω
820
Ω
115
η
F
220
Ω
820
Ω
115
η
F
220
Ω
900
Ω
30
η
F
Figure 7. CLN1204 Wireline Interface Board Jumper Settings
C74
T1
T2
C15
C84
P3
E D C B A
P7
P1
P9
P5
P8
E D C B A
E
D
C
B A
E D
C B
A
√ =
Jumper In
A
= Pin 1 connects to Pin 2
* This setting represents a
standard 600 ohm matching
and is the factory default.
B
= Pin 3 connects to Pin 4
C
= Pin 5 connects to Pin 6
D
= Pin 7 connects to Pin 8
E
= Pin 9 connects to Pin 10
Canada and the U.S wireline
requirements are supported
by Wireline board model
CLN1203.
Note
Summary of Contents for MTR2000 T5544
Page 56: ...Description THIS PAGE INTENTIONALLY LEFT BLANK 68P81096E36 H 13 06 28 05 ...
Page 160: ...VHF Receiver Module 6 68P81096E19 B 09 30 05 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 167: ...VHF Exciter Module 6 68P81096E22 C 09 30 05 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 259: ...DLN6622 500W Power Supply Module 6 68P81011Y31 O 03 10 06 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 271: ...DLN6624 250W Power Supply Module 6 68P81011Y29 O 03 10 06 THIS PAGE INTENTIONALLY LEFT BLANK ...