Getting Started 1 - 13
•
A clean boot resets the mobile computer to the factory default settings.
Data saved in flash memory or a memory card is not lost. Perform a warm boot first. This restarts the mobile
computer and saves all
stored
records and entries. If the mobile computer still does not respond, perform a cold
boot.
Performing a Warm Boot
Hold down the Power button for approximately five seconds. As soon as the mobile computer starts to perform a
warm boot release the
Power
button.
Performing a Cold Boot
A cold boot restarts the mobile computer. The operating system and all applications are restarted. File storage is
preserved. The Real-Time-Clock (RTC) resets.
Only perform a cold boot if a warm boot does not solve the
problem.
To perform a cold boot:
1.
Press the primary battery release on the mobile computer to partially eject the battery from the mobile
computer.
2.
On an MC9090-G, while the battery is partially released, simultaneously press and release the trigger and the
Power
button.
or
On an MC-909X-K or MC909X-S, while the battery is partially released, simultaneously press and release the
left scan button and the
Power
button.
3.
Push the battery to fully re-insert it in the mobile computer. One audible click can be heard as the battery is fully
inserted.
4.
The mobile computer initializes.
Performing a Clean Boot
A clean boot resets the mobile computer to the factory default settings. All data is the
Application
folder is retained.
You must download the Clean Boot Package file from the Symbol Support Central and install on the mobile
computer.
To perform a clean boot:
1.
Download the Clean Boot Package from the Symbol Support Central. Follow the instructions included in the
package for installing the package onto the mobile computer.
2.
Press the primary battery release on the mobile computer to partially eject the battery from the mobile
computer.
3.
On an MC9090-G, while the battery is partially released, simultaneously press and release the trigger and the
Power
button.
or
CAUTION
A clean boot should only be performed by an authorized system administrator. You must connect the
mobile computer to AC power during a clean boot.
Removing AC power from the mobile computer during a clean boot may render the mobile computer
inoperable.
Summary of Contents for MC909X
Page 1: ...MC909X Mobile Computer Integrator Guide ...
Page 2: ......
Page 3: ...MC909X Integrator Guide 72E 72216 06 Rev A December 2007 ...
Page 6: ...iv MC909X Mobile Computer Integrator Guide ...
Page 24: ...xxii MC909X Integrator Guide ...
Page 150: ...4 42 MC909X Integrator Guide ...
Page 220: ...8 14 MC909X Integrator Guide ...
Page 241: ...Staging and Provisioning 9 21 Figure 9 32 UnHide UI Selection ...
Page 252: ...9 32 MC909X Integrator Guide ...
Page 266: ...10 14 MC909X Integrator Guide ...
Page 300: ...B 24 MC909X Integrator Guide ...
Page 314: ...Glossary 14 MC909X Integrator Guide ...
Page 321: ......