9.10.1 Acquisition/Lock Time Definitions
Typical control systems refer to the acquisition time or lock time as the
reaction time of the system, within specified tolerances, to a step input.
In a PLL, the step input occurs when the PLL is turned on or when it
suffers a noise hit. The tolerance is usually specified as a percentage of
the step input or when the output settles to the desired value plus or
minus a percentage of the frequency change. Therefore, the reaction
time is constant in this definition, regardless of the size of the step input.
For example, consider a system with a 5% acquisition time tolerance. If
a command instructs the system to change from 0Hz to 1MHz, the
acquisition time is the time taken for the frequency to reach 1MHz
±
50kHz. 50kHz = 5% of the 1MHz step input. If the system is operating at
1MHz and suffers a –100kHz noise hit, the acquisition time is the time
taken to return from 900kHz to 1MHz
±
5kHz. 5kHz = 5% of the 100kHz
step input.
Other systems refer to acquisition and lock times as the time the system
takes to reduce the error between the actual output and the desired
output to within specified tolerances. Therefore, the acquisition or lock
time varies according to the original error in the output. Minor errors may
not even be registered. Typical PLL applications prefer to use this
definition because the system requires the output frequency to be within
a certain tolerance of the desired frequency regardless of the size of the
initial error.
The discrepancy in these definitions makes it difficult to specify an
acquisition or lock time for a typical PLL. Therefore, the definitions for
acquisition and lock times for this module are as follows:
•
Acquisition time, t
ACQ
, is the time the PLL takes to reduce the error
between the actual output frequency and the desired output
frequency to less than the tracking mode entry tolerance
∆
TRK
.
Acquisition time is based on an initial frequency error,
(f
DES
– f
ORIG
)/f
DES
, of not more than
±
100%. In automatic
9.4.2.3 Manual and Automatic PLL
), acquisition time expires when the ACQ bit
becomes set in the PLL bandwidth control register (PBWC).
Summary of Contents for MC68HC908AB32
Page 1: ...MC68HC908AB32 D REV 1 0 MC68HC908AB32 HCMOS Microcontroller Unit TECHNICAL DATA ...
Page 2: ......
Page 68: ...FLASH Memory Technical Data MC68HC908AB32 Rev 1 0 68 FLASH Memory MOTOROLA ...
Page 84: ...EEPROM Technical Data MC68HC908AB32 Rev 1 0 84 EEPROM MOTOROLA ...
Page 390: ...Ordering Information Technical Data MC68HC908AB32 Rev 1 0 390 Ordering Information MOTOROLA ...
Page 391: ......