MC68HC05L1
MOTOROLA
11-11
CPU CORE AND INSTRUCTION SET
11
11.3
Addressing modes
Ten different addressing modes provide programmers with the flexibility to optimize their code for
all situations. The various indexed addressing modes make it possible to locate data tables, code
conversion tables and scaling tables anywhere in the memory space. Short indexed accesses are
single byte instructions; the longest instructions (three bytes) enable access to tables throughout
memory. Short absolute (direct) and long absolute (extended) addressing are also included. One
or two byte direct addressing instructions access all data bytes in most applications. Extended
addressing permits jump instructions to reach all memory locations.
The term ‘effective address’ (EA) is used in describing the various addressing modes. The
effective address is defined as the address from which the argument for an instruction is fetched
or stored. The ten addressing modes of the processor are described below. Parentheses are used
to indicate ‘contents of’ the location or register referred to. For example, (PC) indicates the
contents of the location pointed to by the PC (program counter). An arrow indicates ‘is replaced
by’ and a colon indicates concatenation of two bytes. For additional details and graphical
illustrations, refer to the
M6805 HMOS/M146805 CMOS Family Microcomputer/
Microprocessor User's Manual or to the M68HC05 Applications Guide.
11.3.1
Inherent
In the inherent addressing mode, all the information necessary to execute the instruction is
contained in the opcode. Operations specifying only the index register or accumulator, as well as
the control instruction, with no other arguments are included in this mode. These instructions are
one byte long.
11.3.2
Immediate
In the immediate addressing mode, the operand is contained in the byte immediately following the
opcode. The immediate addressing mode is used to access constants that do not change during
program execution (e.g. a constant used to initialize a loop counter).
EA = PC+1; PC
←
PC+2
11.3.3
Direct
In the direct addressing mode, the effective address of the argument is contained in a single byte
following the opcode byte. Direct addressing allows the user to directly address the lowest 256
bytes in memory with a single two-byte instruction.
EA = (PC+1); PC
←
PC+2
Address bus high
←
0; Address bus low
←
(PC+1)
TPG
101
Summary of Contents for MC68HC05T16
Page 2: ......
Page 14: ...MOTOROLA vi MC68HC05T16 THIS PAGE LEFT BLANK INTENTIONALLY TPG 12 ...
Page 16: ...MOTOROLA viii MC68HC05T16 THIS PAGE LEFT BLANK INTENTIONALLY TPG 14 ...
Page 18: ...MOTOROLA x MC68HC05T16 THIS PAGE LEFT BLANK INTENTIONALLY TPG 16 ...
Page 54: ...MOTOROLA 5 12 MC68HC05T16 TIMERS 5 THIS PAGE LEFT BLANK INTENTIONALLY TPG 52 ...
Page 64: ...MOTOROLA 6 10 MC68HC05T16 M BUS SERIAL INTERFACE 6 THIS PAGE LEFT BLANK INTENTIONALLY TPG 62 ...
Page 110: ...MOTOROLA 12 4 MC68HC05T16 LOW POWER MODES 12 THIS PAGE LEFT BLANK INTENTIONALLY TPG 108 ...
Page 116: ...MOTOROLA 13 6 MC68HC05T16 OPERATING MODES 13 THIS PAGE LEFT BLANK INTENTIONALLY TPG 114 ...