68P80801E30-A 5/1/2002
4-31
Gen 3 Site Controller System Manual
Chapter 4 Installation
Intercabling Connections
Table 4-16
Alarm intercabling
System/Site Type
Intercabling Connections
Perform Cabling
As Shown In:
800 MHz DUPLEXED RFDS (0182020V06 and earlier)
1-5 Channel Omni
• EAS/EAS2
RF#1
to Main RFC
ALARM
connector
5-8 Channel Duplex Hybrid Expansion
• EAS/EAS2
RF#1
to Main RFC
ALARM
connector
• EAS/EAS2
RF#2
to Expansion RFC
ALARM
connector on Power Supply Tray
9-12 Channel Duplex Hybrid
Expansion
• EAS/EAS2
RF#1
to Main RFC
ALARM
connector
• EAS/EAS2
RF#2
to Expansion RFC #1
ALARM
connector on Power Supply Tray
• EAS/EAS2
RF#3
to Expansion RF Cabinet #2
ALARM
connector on Power Supply Tray
Sectored
• EAS/EAS2
RF#1
to Main RFC #1
ALARM
connector
• EAS/EAS2
RF#2
to Main RFC #2
ALARM
connector
• EAS/EAS2
RF#3
to Main RFC #3
ALARM
connector
800 MHz GEN 4 DUPLEXED RFDS
1-6 Channel Omni
• EAS/EAS2
RF#1
to Main RFC alarm connector
on Rx Tray
7-12 Channel Omni Expansion
• EAS/EAS2
RF#1
to Main RFC alarm connector
on Rx Tray
• EAS/EAS2
RF#2
to Expansion RFC alarm
connector on Rx Tray
13-18 Channel Omni Expansion
• EAS/EAS2
RF#1
to Main RFC alarm connector
on Rx Tray
• EAS/EAS2
RF#2
to Expansion RFC #1 alarm
connector on Rx Tray
• EAS/EAS2
RF#3
to Expansion RFC #2 alarm
connector on Rx Tray