Chapter 6 System Testing
Gen 3 Site Controller System Manual
Site Controller Verification
6-4
68P80801E30-A 5/1/2002
Site Controller Test Equipment
Table 6-1 lists the recommended test equipment for the site controller. This
test equipment only applies to the site controller testing procedure.
Service Computer Startup
This procedure assumes that power is applied to the system. If power is not
applied, perform the procedures in the Final Checkout chapter.
Whenever the following procedures instruct you to enter software
commands, this manual presents the commands in bold lettering. Enter all
commands exactly as they appear. The command prompt precedes the
command, as in the following example:
iSC>
whois isc
Table 6-1
Test equipment for cabinet testing
Equipment
Model/type
Supplier
Description
service computer *
80286 or better
IBM
®
, IBM
compatible, or
Macintosh
local service computer
T1/E1 test set
Fireberd
TTC
used to generate a Quasi Random Signal
Sequence (QRSS) bit pattern and
perform a loop-back test
T1/E1 test cable
n/a
locally procured
connects the T1 test set to the customer
maintained T1 circuit
RS-232 cable
n/a
locally procured
straight through connecting cable with
DB9 connector for site controller port
communication
software
ProComm Plus (except
version 2.0.1)
(or equivalent)
DataStorm
Technologies
host communication
* Either a DOS-based computer or Macintosh computer may be used for the service computer. Contact your iDEN System
Manager for additional information.