5.11.3 Measuring HPD BR Tx Power, Frequency Accuracy and Tx EVM
9
On the
Test and Measurement Screen
:
a. Click
Change to Service Mode
.
b. Re-open the Test and Measurement Screen.
c. Key up the base radio for 16-QAM modulation by selecting
16-QAM
in the Select Pattern to Transmit field.
d. Click
Start Pattern Transmission
.
Figure 5-26
CSS Test and Measurement Screen
10
Display the base radios transmission readings on the service monitors Rx Meter subscreen, as follows: A panel
of soft keys displays on the right side of the screen, including two
Reset
keys.
a. Click the Rx Meter subscreen.
Step result:
A panel of soft keys displays on the right side of the screen, including two
Reset
keys.
b. Click the
Reset Acquire
soft key on the right side of the screen. This re-synchronizes the test set with the
incoming signal.
c. Click the
Reset Meters
soft key on the right side of the screen. This stops, clears, and restarts the acquisition
of data for the data display fields.
Figure 5-27
HPD Service Monitor - Rx Meter Subscreen, Reset Soft Keys (Aeroflex 3900
Series Service Monitor)
6871022P86-A - November 2012
5-51
Summary of Contents for GTR 8000
Page 2: ......
Page 4: ......
Page 6: ......
Page 14: ......
Page 18: ......
Page 22: ......
Page 26: ......
Page 60: ......
Page 177: ...5 8 1 3 VHF Tuning Procedure Figure 5 1 Preselector Tuning VHF 6871022P86 A November 2012 5 7 ...
Page 181: ...5 8 2 3 UHF Tuning Procedure Figure 5 2 Preselect Tuning UHF 6871022P86 A November 2012 5 11 ...
Page 230: ......
Page 234: ......
Page 244: ......
Page 286: ......
Page 300: ......
Page 338: ......