Con
fi
guring Redundant Site Controller
Chapter 15: Expansion Options
Procedure 15-8
Configure Ethernet Ports (Continued)
6
From the prompt, run the command
spw inet/if/eth0 “dhcp:no
addr:10.0.253.X mask:255.255.255.0 dev_name:tsec dev_unit:0
ethaddr:yy:yy:yy:yy:yy:yy mtu:1500”
•
X
= 1 for SC1, and 2 for SC2
•
yy:yy:yy:yy:yy:yy
= the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
7
From the prompt, run the command
spw inet/if/eth1 “dhcp:no
addr:10.0.254.X mask:255.255.255.0 dev_name:tsec1 dev_unit:1
ethaddr:yy:yy:yy:yy:yy:yy mtu:1500”
•
X = 1 for SC1, and 2 for SC2
•
yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
8
Remember to check the IP settings on both SCs.
For an MTS using a single Site Controller, the Ethernet settings should be checked
using the
ifconfig -a
command from the SC application prompt. From the
output, con
fi
rm that the eth0 and eth1 ports are con
fi
gured as expected. See Procedure
below for more information on how to set SC IDs.
Procedure 15-9
Configure Site Controller IDs
The Site Controllers must have different ID values con
fi
gured. To check
the SC id, follow the steps below.
1
Log onto the Site Controller Application MMI.
2
From the SC: prompt, run the command
id
.
3
An id value of either A or B is displayed.
4
Perform the same check on the second Site Controller.
15-32
6802800U74-N September 2009
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...